2021
DOI: 10.1038/s41598-021-96589-w
|View full text |Cite
|
Sign up to set email alerts
|

A quality optimization approach to image Achilles tendon microstructure by phase-contrast enhanced synchrotron micro-tomography

Abstract: Achilles tendons are mechanosensitive, and their complex hierarchical structure is in part the result of the mechanical stimulation conveyed by the muscles. To fully understand how their microstructure responds to mechanical loading a non-invasive approach for 3D high resolution imaging suitable for soft tissue is required. Here we propose a protocol that can capture the complex 3D organization of the Achilles tendon microstructure, using phase-contrast enhanced synchrotron micro-tomography (SR-PhC-μCT). We in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(14 citation statements)
references
References 72 publications
1
13
0
Order By: Relevance
“…Finally, this study was purely anatomical; therefore, we could not provide quantitative measurements related to ACL force. Techniques, such as contrast-enhanced X-ray CT and phase contrast-enhanced synchrotron X-ray micro-tomography, may be useful for the quantitative evaluation of the ACL fascicle alignment 45 47 . In the future, a biomechanical study may provide additional information regarding the mechanisms of ACL injury.…”
Section: Discussionmentioning
confidence: 99%
“…Finally, this study was purely anatomical; therefore, we could not provide quantitative measurements related to ACL force. Techniques, such as contrast-enhanced X-ray CT and phase contrast-enhanced synchrotron X-ray micro-tomography, may be useful for the quantitative evaluation of the ACL fascicle alignment 45 47 . In the future, a biomechanical study may provide additional information regarding the mechanisms of ACL injury.…”
Section: Discussionmentioning
confidence: 99%
“…The thawed meniscus samples were imaged using SR-PhC-mCT at the TOMCAT beamline at the Swiss Light Source (Paul Scherrer Institute, Switzerland) 22 . The setup was optimized as previously described for tendon tissue by Pierantoni et al 13 . The images were acquired using the High Numerical Aperture Microscope setup (4 magnification, field of view of 4.2 mm  3.5 mm and pixel size of 1.625 mm) coupled to a LuAG:Ce scintillator screen of 150 mm.…”
Section: Phase Contrast Enhanced Tomographic Imagingmentioning
confidence: 99%
“…The power spectrum was calculated by applying a fast Fourier transform to the data and spatial resolution was defined as the frequency where the intensity was two times the noise level, as suggested by Modregger et al 25 . The noise level was defined as the value that the power spectrum converged to which was found by averaging the spectrum over the last third of the frequencies 13,25,26 . Spatial resolution can be defined as the minimum distance at which two features can be resolved in the image 27 .…”
Section: Spatial Resolutionmentioning
confidence: 99%
See 2 more Smart Citations