2021 IEEE 4th International Conference on Electronic Information and Communication Technology (ICEICT) 2021
DOI: 10.1109/iceict53123.2021.9531099
|View full text |Cite
|
Sign up to set email alerts
|

A Quantitative Study of CVD Graphene on Synthesis Parameters and Sheet Resistance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 8 publications
1
3
0
Order By: Relevance
“…The measured results of the orthogonal experiment is shown in Figure 4, the tunning range of GSS composed of graphene sheets measured by waveguide method in group_4 is the largest, which varies from 430−1840 Ω/sq. Combining our previous work [26], it can be seen that the demands for growth parameters are consistent when pursuing the lowest static sheet resistance and the biggest tunning range of graphene. This can be understood by the best flatness and integrity of graphene sample grown under the parameter of group_4 as shown in Figure 5a.…”
Section: Impact Of Growth Parameterssupporting
confidence: 57%
See 3 more Smart Citations
“…The measured results of the orthogonal experiment is shown in Figure 4, the tunning range of GSS composed of graphene sheets measured by waveguide method in group_4 is the largest, which varies from 430−1840 Ω/sq. Combining our previous work [26], it can be seen that the demands for growth parameters are consistent when pursuing the lowest static sheet resistance and the biggest tunning range of graphene. This can be understood by the best flatness and integrity of graphene sample grown under the parameter of group_4 as shown in Figure 5a.…”
Section: Impact Of Growth Parameterssupporting
confidence: 57%
“…The dynamic tunning range of graphene is measured through the waveguide method, as shown in Figure 2a, which is a kind of noncontact measurement method. It should be noted that the dynamic tunning range is unable to be measured by the commonly used four-probe method [17,26] because the conductive part (graphene) is wrapped by its transfer substrate. The waveguide used for measuring the dynamic sheet resistance of graphene is WR90 (8.2-12.4 GHz) and the vector network analyzer used is purchased from Agilent Co. Ltd., Santa Clara, CA, USA, (ZNB-40, 10-40 GHz).…”
Section: Improvement Of Waveguide Methodsmentioning
confidence: 99%
See 2 more Smart Citations