1984
DOI: 10.1088/0022-3719/17/1/019
|View full text |Cite
|
Sign up to set email alerts
|

A rapid, exact curved-wave theory for EXAFS calculations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
362
0

Year Published

1985
1985
2017
2017

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 689 publications
(366 citation statements)
references
References 9 publications
4
362
0
Order By: Relevance
“…Details of the EXAFS data analysis performed using the program Viper, 23 and of the EXAFS fitting performed using the modular package DL_EXCURV, based on the EXCURV98 code, [24][25][26][27][28] are reported in the ESI.…”
Section: Experimental Synthesismentioning
confidence: 99%
“…Details of the EXAFS data analysis performed using the program Viper, 23 and of the EXAFS fitting performed using the modular package DL_EXCURV, based on the EXCURV98 code, [24][25][26][27][28] are reported in the ESI.…”
Section: Experimental Synthesismentioning
confidence: 99%
“…XAS Data Analysis-Standard EXAFS analysis was performed using the EXPROG software package (developed by C. Hermes and H. F. Nolting at the European Molecular Biology Laboratory-Outstation/ Hamburg, Germany) to process the raw data and EXCURV98 (developed by N. Binsted, S. W. Cambell, S. J. Gurman, and P. Stepherson at Science and Engineering Research Council, Daresbury, UK) using exact curve wave scattering theory (19,20) to analyze the spectra. The energy range was set to 30 -650 eV above the edge.…”
Section: X-ray Absorption Spectroscopymentioning
confidence: 99%
“…Model ¢tting was carried out with EXCURV90 using curved-wave theory and ab initio phase shift [29], with the edge positions being determined from the ¢rst in£ection points of the derivative spectra. The phase shifts experienced by the photoelectron, the amplitude of the backscattering and the electron mean free path were calculated from within EX-CURV90 using spherical wave theory and a single scattering model.…”
Section: Exafs Data Analysismentioning
confidence: 99%
“…The model compounds zinc sulphide (Zn-S 4 2.35 A î ) [30], zinc formate dihydrate (Zn-O 6 2.107 A î , averaged) [31] and zinc tetraphenylporphyrin (Zn-N 4 2.037 A î , averaged) [32] were used to check the validity of the ab initio phase shifts and amplitudes for sulphur, oxygen and nitrogen backscatterers respectively, and to establish the general parameters, AFAC (proportion of absorption causing EXAFS) and VPI (allows for inelastic scattering of the photoelectron) [29]. During least-squares ¢tting it is important to avoid correlation e¡ects between those parameters which strongly a¡ect the EXAFS amplitude and between those that in£uence the frequency of the EXAFS oscillations.…”
Section: Exafs Data Analysismentioning
confidence: 99%