2023
DOI: 10.1016/j.toxicon.2023.107282
|View full text |Cite
|
Sign up to set email alerts
|

A rapid LC-MS/MS method for multi-class identification and quantification of cyanotoxins

Fernanda Rios Jacinavicius,
Thaíssa Giovanna Valverde Campos,
Larissa Souza Passos
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 38 publications
0
3
0
Order By: Relevance
“…Other, total concentrations found for MCs range between 0.1-220 µg/L, and between 0.06-1400 µg/L as free toxins. Saxitoxins, mostly represented by the main analogue, STX, as described in section 2.2, were generally present in concentrations below 25 µg/L, although higher concentrations were measured at three sites 63 and 420 µg/L (site 17-21 and 17-22), including the highest concentration found för STX, 1890 µg/L (site [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33]. CYN was detected in concentrations up to 9.5 µg/L (site 17-37), while ATXs were present up to 4.2 µg/L (Så1), of which hATX was detected in five samples and always at levels ≤LOQ of the method (up to 0.1 µg/L, calculated as average of three samplings within the same cyanobloom).…”
Section: Cyanotoxin Quantitiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Other, total concentrations found for MCs range between 0.1-220 µg/L, and between 0.06-1400 µg/L as free toxins. Saxitoxins, mostly represented by the main analogue, STX, as described in section 2.2, were generally present in concentrations below 25 µg/L, although higher concentrations were measured at three sites 63 and 420 µg/L (site 17-21 and 17-22), including the highest concentration found för STX, 1890 µg/L (site [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33]. CYN was detected in concentrations up to 9.5 µg/L (site 17-37), while ATXs were present up to 4.2 µg/L (Så1), of which hATX was detected in five samples and always at levels ≤LOQ of the method (up to 0.1 µg/L, calculated as average of three samplings within the same cyanobloom).…”
Section: Cyanotoxin Quantitiesmentioning
confidence: 99%
“…In general, mass spectrometry (MS) based methods have become more commonly applied in the analysis of cyanotoxins in recent years compared to other techniques [29][30][31][32][33], where Ultra-Performance Liquid Chromatography (UPLC-MS/MS) has been most often preferred in the detection with quantification of cyanotoxins in various sample matrices [34][35][36][37].…”
Section: Introductionmentioning
confidence: 99%
“…In general, mass spectrometry (MS)-based methods have become more commonly applied in the analysis of cyanotoxins in recent years compared to other techniques [29][30][31][32][33], where Ultra-Performance Liquid Chromatography (UPLC-MS/MS) has been most often preferred for detection with the quantification of cyanotoxins in various sample matrices [34][35][36][37].…”
Section: Introductionmentioning
confidence: 99%