2021
DOI: 10.1039/d1ay01162f
|View full text |Cite
|
Sign up to set email alerts
|

A ratiometric triazine-based colorimetric and fluorometric sensor for the recognition of Zn2+ ions and its application in human lung cancer cells

Abstract: Herein, we introduce a new ratiometric 2,4,6-triamino-1,3,5-triazine-based probes (R1 and R2) having three different binding sites for three metal ion binder which can selectively detect Zn2+ ions and particularly the...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 40 publications
0
11
0
Order By: Relevance
“…The cells were washed with 1× PBS and then they were mounted on a glass slide and observed under a fluorescence microscope (Olympus) using a DAPI filter. 48 Synthesis of compounds 2-5…”
Section: Papermentioning
confidence: 99%
“…The cells were washed with 1× PBS and then they were mounted on a glass slide and observed under a fluorescence microscope (Olympus) using a DAPI filter. 48 Synthesis of compounds 2-5…”
Section: Papermentioning
confidence: 99%
“…Hence, 10 μM was selected as the working concentration of the ligand TPSZ to perform further studies. 36,37…”
Section: Realistic Sensing Applicationsmentioning
confidence: 99%
“…Hence, 10 μM was selected as the working concentration of the ligand TPSZ to perform further studies. 36,37 Results from fluorescence microscopy imaging showed an increased level of fluorescence intensity at an emission wavelength of 420 nm (blue emission) when the MDA-MB 231 cells were exposed to the ligand TPSZ (10 μM) in combination with OCl − (10 μM) for incubation periods of 15 min and 30 min (Fig. 11(a)).…”
Section: Fluorescence Imagingmentioning
confidence: 99%
“…Briey, the cells were grown in coverslips for 24 h in a 37 C humidied incubator containing 5% CO 2 and then either mock-treated or treated with 10 mM of the ligand MNBTZ in the presence or absence of a 5 mM working concentration of cyanide and incubated for 15 min or 30 min in the dark at 37 C. The cells were then washed with 1Â PBS three times to remove any unbound MNBTZ, then mounted on a glass slide and observed under a uorescence microscope (Olympus) using a DAPI lter. 34,35 Fig. 6…”
Section: Fluorescence Imagingmentioning
confidence: 99%
“…The cells were then washed with 1× PBS three times to remove any unbound MNBTZ , then mounted on a glass slide and observed under a fluorescence microscope (Olympus) using a DAPI filter. 34,35…”
Section: Live-cell Imagingmentioning
confidence: 99%