2007
DOI: 10.1109/tmi.2007.901991
|View full text |Cite
|
Sign up to set email alerts
|

A Reconstruction Method for Gappy and Noisy Arterial Flow Data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
33
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 35 publications
(33 citation statements)
references
References 32 publications
0
33
0
Order By: Relevance
“…Subsequently, Gappy POD has shown substantial capabilities to accurately reconstruct physical processes from partial-field measurement data, especially for fluid flow problems [25][26][27][28][29], and has even been investigated for use in creating surrogate mappings (as described in Section 1) to solve design-type inverse problems [26].…”
Section: Gappy Proper Orthogonal Decompositionmentioning
confidence: 99%
“…Subsequently, Gappy POD has shown substantial capabilities to accurately reconstruct physical processes from partial-field measurement data, especially for fluid flow problems [25][26][27][28][29], and has even been investigated for use in creating surrogate mappings (as described in Section 1) to solve design-type inverse problems [26].…”
Section: Gappy Proper Orthogonal Decompositionmentioning
confidence: 99%
“…November 23, 2016 uses the adjoint method for computationally efficient gradient calculations, to produce the final estimate of the material property distribution. The three-step ((1) Gappy POD, (2) direct inversion, and (3) gradient-based optimization) inverse characterization approach is evaluated through simulated test problems based on the characterization of elastic modulus distributions with localized variations (e.g., inclusions) within simple structures.…”
Section: Preprint Submitted To Computational Mechanicsmentioning
confidence: 99%
“…Subsequently, Gappy POD has shown substantial capabilities to accurately reconstruct physical processes from partial-field measurement data, especially for fluid flow problems [20,21,22,23,24].…”
Section: Direct Inversion With Gappy Podmentioning
confidence: 99%
“…As a first step, the artifacts and noise should be, if possible, identified and treated prior to using medical images for acquisition of clinical data. 36 To estimate if the suggested procedure can be used with relatively low time resolution imaging equipment we performed the following computations. We selected 800 time instants throughout the cycle and assumed Fig.…”
Section: Pod In the Clinical Settingmentioning
confidence: 99%