2018
DOI: 10.1186/s13014-018-1125-8
|View full text |Cite
|
Sign up to set email alerts
|

A remote EPID-based dosimetric TPS-planned audit of centers for clinical trials: outcomes and analysis of contributing factors

Abstract: BackgroundA novel remote method for external dosimetric TPS-planned auditing of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for clinical trials using electronic portal imaging device (EPID) has been developed. The audit has been applied to multiple centers across Australia and New Zealand. This work aims to assess the audit outcomes and explores the variables that contributed to the audit results.MethodsThirty audits were performed of 21 radiotherapy facilities, 17 facil… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(12 citation statements)
references
References 20 publications
0
11
0
1
Order By: Relevance
“…37 Therefore, the penumbra differences (≤1.1 mm) observed in Figures 4 cannot be attributed to a film limitation, and seems due to the modelling of the VIPER software, which has not been specifically optimized for small fields. 15 Hence, although there is margin for improvement in the VIPER modeling of the penumbra, it is still adequate for the purposes of this work.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…37 Therefore, the penumbra differences (≤1.1 mm) observed in Figures 4 cannot be attributed to a film limitation, and seems due to the modelling of the VIPER software, which has not been specifically optimized for small fields. 15 Hence, although there is margin for improvement in the VIPER modeling of the penumbra, it is still adequate for the purposes of this work.…”
Section: Discussionmentioning
confidence: 98%
“…Ansbacher described a method for rapid evaluation of IMRT plans, using EPID images for reconstruction of the dose delivered to a virtual 3D cylindrical phantom 13 . A similar method was used by the VIPER (VIrtual Phantom Epid dose Reconstruction) software developed at Calvary Mater Newcastle Hospital (CMNH) that has been used for remote EPID‐based external dosimetric auditing of IMRT and VMAT for clinical trials 14,15 . VIPER is not currently commercially available, but it can be made available on request for research purposes.…”
Section: Introductionmentioning
confidence: 99%
“…DVH calculation, however, is not currently available in the VIPER software. The implementation of a DVH approach in the VIPER software was also proposed by Miri et al [22]; 4. 3D dose distribution reconstruction on the patient's CT anatomy cannot be done by the VIPER software, as it is currently performed by other commercially-available systems [41,42]; 5.…”
Section: Discussionmentioning
confidence: 99%
“…3D dose distribution reconstruction on the patient's CT anatomy cannot be done by the VIPER software, as it is currently performed by other commercially-available systems [41,42]; 5. As pointed out by Miri et al [22], VIPER does not allow an end-to-end audit to be performed, for instance, absolute beam output, beam profile or inhomogeneity modelling cannot been assessed.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation