2015
DOI: 10.1039/c5ay01402f
|View full text |Cite
|
Sign up to set email alerts
|

A reversed phase HPLC-DAD method for the determination of phenolic compounds in plant leaves

Abstract: A simple, fast and efficient HPLC-DAD method was developed for the determination of phenolic compounds in grape leaves. The best separation was achieved in 40 min using gradient elution of methanol, deionized water and acetic acid on Zorbax plus C18 column (4.6 × 100 mm, 3.5 µm) at 25 °C. The phenolic compounds were identified with the help of diode array detector at 280, 320 and 360 nm. The method was precise, accurate, specific and highly reproducible for quantitative and qualitative purposes. The method was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
55
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1
1

Relationship

5
4

Authors

Journals

citations
Cited by 86 publications
(57 citation statements)
references
References 24 publications
2
55
0
Order By: Relevance
“…Centrifugation was carried out and again filtered to HPLC vials using Agilent PTFE injection filter (0.45 μm). The residue of the spinach extract was dissolved in methanol–water mixture (60:40, v/v), followed by filtration to HPLC vials …”
Section: Methodsmentioning
confidence: 99%
“…Centrifugation was carried out and again filtered to HPLC vials using Agilent PTFE injection filter (0.45 μm). The residue of the spinach extract was dissolved in methanol–water mixture (60:40, v/v), followed by filtration to HPLC vials …”
Section: Methodsmentioning
confidence: 99%
“…The binary gradient system consists of solvent A (methanol:acetic acid:deionized water, 10:2:88, v / v / v ) and solvent B (methanol: acetic acid: deionized water, 90:2:8, v / v / v ). The gradient program used was started from 100% A to 85% A at 5 min, and then 50% A at 20 min, 30% A at 25 min, and 100% B from 30 to 40 min [ 16 ]. The elution was achieved at 25 min due to the elution of all compounds present.…”
Section: Methodsmentioning
confidence: 99%
“…The separation was achieved with the help of Agilent Rapid Resolution Zorbax Eclipse plus C18 (4.6 × 100 mm, 3.5 µm) column, which was maintained at 25 °C. The gradient system consists of solvent A (methanol:acetic acid:deionized water, 10:2:88) and solvent B (methanol:acetic acid:deionized water, 90:2:8) (Zeb 2015 ). The gradient program was started with 100 % A at 0 min, 85 % A at 5 min, 50 % A at 20 min, 30 % A at 25 min, and 100 % B from 30 to 40 min.…”
Section: Methodsmentioning
confidence: 99%