2014
DOI: 10.1371/journal.pone.0105682
|View full text |Cite
|
Sign up to set email alerts
|

A Semi-Automated Technique Determining the Liver Standardized Uptake Value Reference for Tumor Delineation in FDG PET-CT

Abstract: Background 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)-computed tomography (CT) has been an essential modality in oncology. We propose a semi-automated algorithm to objectively determine liver standardized uptake value (SUV), which is used as a threshold for tumor delineation.MethodsA large spherical volume of interest (VOI) was placed manually to roughly enclose the right lobe (RL) of the liver. For each voxel in this VOI, a coefficient of variation of voxel values (CVv) was calculated for… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
82
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
2

Relationship

5
4

Authors

Journals

citations
Cited by 86 publications
(84 citation statements)
references
References 25 publications
2
82
0
Order By: Relevance
“…In accordance with PERCIST 1.0 (17), the SUV mean within a 3-cm spheric volume of interest (VOI) within the right liver lobe is used to obtain the liver background activity. To minimize intra-and interuser variability, this 3-cm VOI is semiautomatically placed using an algorithm that showed high reliability and reproducibility in evaluating liver background activity (18).…”
Section: Software Workflowmentioning
confidence: 99%
“…In accordance with PERCIST 1.0 (17), the SUV mean within a 3-cm spheric volume of interest (VOI) within the right liver lobe is used to obtain the liver background activity. To minimize intra-and interuser variability, this 3-cm VOI is semiautomatically placed using an algorithm that showed high reliability and reproducibility in evaluating liver background activity (18).…”
Section: Software Workflowmentioning
confidence: 99%
“…Computer-aided analysis of PET images for MTV calculations was performed using MIM Maestro software suite, version 5.1 (MIM Software, Cleveland, OH) and using METAVOL 30 (University of California, Los Angeles, CA), with exclusion of urinary, myocardial, and brain 18 FDG uptake. For correlations between MTV and Ig-HTS on patients where such assessments were not available on exactly the same date, Ig-HTS value from the closest date was used as long as these were within 28 days.…”
Section: No Treatmentmentioning
confidence: 99%
“…In addition, FMISO accumulation volume was measured using a software package (Metavol) that we developed previously to conduct volume-based analyses of PET images [31]. The FMISO accumulation volume was automatically contoured using a threshold of 1.3-fold cerebellar mean SUV [19].…”
Section: Methodsmentioning
confidence: 99%