2022
DOI: 10.1016/j.aca.2022.339599
|View full text |Cite
|
Sign up to set email alerts
|

A sensing platform of molecular imprinted polymer-based polyaniline/carbon paste electrodes for simultaneous potentiometric determination of alfuzosin and solifenacin in binary co-formulation and spiked plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
15
0
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 35 publications
(18 citation statements)
references
References 46 publications
1
15
0
2
Order By: Relevance
“…Many factors can influence the precision of the SC-ISE, especially temperature and pH among other experimental parameters such as weighing and pipetting. But the high precision reported in our work and similar ion-selective electrodes reported in the literature [38][39][40] can be attributed to the logarithmic nature of potentiometric response with changing the ion concentration (potential difference of 1 mV means a 4 % change in ion activity for a monovalent ion), the accuracy and precision of the measuring device (0.1 mV resolution, + /À 0.2 mV accuracy), the well-controlled measuring parameters such as cell temperature, electrode selectivity, and the presence of a graphene nanocomposite layer which significantly minimized the potential drift and enhanced the repeatability of the SC-ISE (minimum drift and complete reversibility without any memory) are important factors in achieving accurate and precise results of ISE.…”
Section: Potentiometric Sensors Characterizationsupporting
confidence: 85%
“…Many factors can influence the precision of the SC-ISE, especially temperature and pH among other experimental parameters such as weighing and pipetting. But the high precision reported in our work and similar ion-selective electrodes reported in the literature [38][39][40] can be attributed to the logarithmic nature of potentiometric response with changing the ion concentration (potential difference of 1 mV means a 4 % change in ion activity for a monovalent ion), the accuracy and precision of the measuring device (0.1 mV resolution, + /À 0.2 mV accuracy), the well-controlled measuring parameters such as cell temperature, electrode selectivity, and the presence of a graphene nanocomposite layer which significantly minimized the potential drift and enhanced the repeatability of the SC-ISE (minimum drift and complete reversibility without any memory) are important factors in achieving accurate and precise results of ISE.…”
Section: Potentiometric Sensors Characterizationsupporting
confidence: 85%
“…biosenzore s ugljikovom pastom. CMCPE u svojem sastavu imaju modifikator kemijskog podrijetla, [28][29][30][31][32][33][34][35][36] dok biosenzori imaju modifikator podrijetlom iz prirode, primjerice alge, 2,37-39 bakterije, 40,41 makromolekule iz biljaka kao što su keratin, hitin i dr. [42][43][44] CPE se modificiraju da bi se poboljšala selektivnost mjerenja. Zbog jednostavnosti pripreme, u najvećem broju slučajeva modifikator se u pastu dodaje zajedno s ostalim komponentama.…”
Section: Uvodunclassified
“…Electrodes fabrication. The employed carbon paste was obtained through mixing 8.0 g graphite and 2.0 g MWCNTs powders with 4.3 g paraffin oil in a mortar for about 30 min 8 . CPE cavity was packed with this paste.…”
Section: Materials and Reagentsmentioning
confidence: 99%
“…The latter is usually easily handled and fabricated (e.g. using a carbon paste), economically feasible, and widely applicable compared to liquid contact one [3][4][5][6][7][8] . However, SC-ISEs suffer from main obstacle related to the creation of an aqueous layer between the lower solid support and the upper ion selective polymeric matrix.…”
mentioning
confidence: 99%