2015
DOI: 10.1016/j.jelechem.2014.12.042
|View full text |Cite
|
Sign up to set email alerts
|

A sensitive simultaneous determination of dopamine, acetaminophen and indomethacin on a glassy carbon electrode coated with a new composite of MCM-41 molecular sieve/nickel hydroxide nanoparticles/multiwalled carbon nanotubes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 47 publications
0
13
1
Order By: Relevance
“…This LOD is low, compared to the result of Babaei et al. [ 141 ] The selective use of the modified GCE electrode was validated by the recovery study of DA in synthetic cerebrospinal fluid with good recovery.…”
Section: Detection Of Nts Using Cnt‐based Sensorsmentioning
confidence: 76%
See 1 more Smart Citation
“…This LOD is low, compared to the result of Babaei et al. [ 141 ] The selective use of the modified GCE electrode was validated by the recovery study of DA in synthetic cerebrospinal fluid with good recovery.…”
Section: Detection Of Nts Using Cnt‐based Sensorsmentioning
confidence: 76%
“…In this manner of reasoning, Babaei and his team designed a modified GCE by placing a suspension made from the combination of MWCNTs, Ni(OH) 2 nanoparticles (NHNPs), and MCM‐41 on a GCE. [ 141 ] The electrode thus formed was designated MWCNTs‐NHNPs‐MCM‐41/GCE. Using the DPV for simultaneous determination of DA, PAR, and INDO at the modified electrode, LOD of 0.15, 0.11, and 0.31 µM, respectively, were reported while respective LOD of 0.14, 0.19, and 0.25 µM were reported with CA.…”
Section: Detection Of Nts Using Cnt‐based Sensorsmentioning
confidence: 99%
“…The limits of detection of DA and PA are lower, comparable or in some cases a little bit higher than those obtained using other electrochemical sensors. However, the proposed procedure of the sensor preparation is much simpler than procedures described in the literature with a lower detection limit . The performance of PbF/Nafion/BDD electrode showed a promising tool for the simultaneous electrochemical determination of DA and PA.…”
Section: Resultsmentioning
confidence: 99%
“…Many papers describe the application of modified electrodes to DA and PA assay. It is common to use a multiwalled carbon nanotubes modified glassy carbon electrode which are additionally acid functionalized or modified with graphene oxide , disordered mesoporous silica , cobalt nanoparticles , nickel(II) hydroxide nanoparticles and MCM‐41molecular sieve or graphite nanosheets . Other working electrodes used for the simultaneous voltammetric determination of DA and PA are: single‐wall carbon nanotubes modified carbon‐ceramic electrode , pyrolytic carbon film electrode , poly overoxidized pyrrole‐aszophloxine‐gold modified electrode , glassy carbon electrode modified with (4‐ferrocenylethyne) phenylamine functionalized graphene sheets coupling with chitosan , glassy carbon electrode modified with nanocomposite of ferrocene thiolate stabilized Fe 3 O 4 @Au nanoparticles with graphene sheet/chitosan , glassy carbon electrode modified with highly loaded zirconium oxide nanoparticles decorated reduced graphene oxide , glassy carbon electrode modified with Ag‐nanoparticle with 4‐nitro phenylcyanamide ligand , glassy carbon electrode modified with porous gold nanosheets or PbS nanoparticles Schiff base‐modified carbon paste electrode .…”
Section: Introductionmentioning
confidence: 99%
“…Although these methods successfully detect indomethacin in pharmaceutical and biological samples, some of them lack sensitivity and involve tedious procedure (time consuming or expensive). Owing to their highly‐sensitive, rapid and online detection ability, etc., electrochemical sensors have become increasingly popular for quantitative determination of indomethacin …”
Section: Introductionmentioning
confidence: 99%