2014
DOI: 10.1039/c3ay42159g
|View full text |Cite
|
Sign up to set email alerts
|

A sequential injection lab-at-valve (SI-LAV) platform for hydride generation atomic absorption spectrometry (HG-AAS): on-line determination of inorganic arsenic

Abstract: A sequential injection lab-at-valve (SI-LAV) platform for hydride generation atomic absorption spectrometry (HG-AAS).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 24 publications
0
9
0
Order By: Relevance
“…215 Also, optic fibers were used for light inand out-coupling in the incorporated detection flow cell of the integrated selection valve. In another recently reported approach, in an SIA system with hydride generation atomic absorption spectrometry for determination of inorganic arsenic, a conventional six-port selection valve was integrated with a gas-liquid separation/reaction chamber, 216 which minimized dispersion and possible loss of the generated arsine.…”
Section: Recent Developments In Design Of Flow-injection Measuring Sy...mentioning
confidence: 99%
See 1 more Smart Citation
“…215 Also, optic fibers were used for light inand out-coupling in the incorporated detection flow cell of the integrated selection valve. In another recently reported approach, in an SIA system with hydride generation atomic absorption spectrometry for determination of inorganic arsenic, a conventional six-port selection valve was integrated with a gas-liquid separation/reaction chamber, 216 which minimized dispersion and possible loss of the generated arsine.…”
Section: Recent Developments In Design Of Flow-injection Measuring Sy...mentioning
confidence: 99%
“…The use of a multiposition SIA valve integrated with a gas-liquid separation/ reaction chamber has been already mentioned above. 216 An improvement of arsenic speciation in an FIA system with HG-AAS detection was reported by the use of on-line prereduction of pentavalent arsenicals by thioglycolic acid, as were the preconcentration and separation of arsines by means of cryotrapping in a packed reactor in a liquid nitrogen. 317 In a recent publication on the development of an FIA system for arsenic determination, the HPLC instrumentation was combined with a hydride generation-AAS detection, and a highresolution continuum radiation source operating with a Xenon short-arc lamp.…”
Section: Atomic Spectroscopy Detectionsmentioning
confidence: 99%
“…The same research group also used the device for the determination of As in water. 123 For a 3 mL sample and sampling frequency of 11 h À1 , the LOD was 0.15 mg L À1 and the precision 3.2% (n ¼ 10) at 2.0 mg L À1 .…”
Section: Vapour Generationmentioning
confidence: 94%
“…[13][14][15][16] The quantitative techniques used for the determination of Pb mainly include inductively coupled plasma optical emission spectrometry (ICP-OES), 17 inductively coupled plasma atomic emission spectrometry (ICP-AES), 18 inductively coupled plasma mass spectrometry (ICP-MS), 5 ame atomic absorption spectrometry (F-AAS), 19,20 and graphite furnace atomic absorption spectrometry. 21 Several methods have been described for the determination of As such as hydride generation atomic absorption spectrometry (HG-AAS), 22 ICP-OES 17 and ICP-MS. 23 Additionally, instrumental neutron activation analysis (INAA) 24 can be applied in the direct analysis of solid cosmetics thereby avoiding laborious sample preparation processes.…”
Section: Introductionmentioning
confidence: 99%