2024
DOI: 10.1039/d3ra07960k
|View full text |Cite
|
Sign up to set email alerts
|

A simple and reliable QSPR model for prediction of chromatography retention indices of volatile organic compounds in peppers

Shahin Ahmadi,
Shahram Lotfi,
Hamideh Hamzehali
et al.

Abstract: A simple and reliable QSPR model for the retention indices (RIs) of 273 identified volatile organic compounds (VOCs) of different types of pepper was developed with CORAL software. The proposed theoretical model is applied to estimate the retention indices (RIs) of new VOCs.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 50 publications
0
2
0
Order By: Relevance
“…Thus, the procedure of MD selection was repeated many times and each time Also, the accuracy of the model (and of the method in general) depends on the set of selected features. Typically, in QSRR works, a set of MD is selected only once [17][18][19][20][21][22] and then the accuracy of the model is carefully investigated (see Fig. 2C) using cross-validation or one-leave-out approaches.…”
Section: Evaluation Of the Molecular Descriptor Selection Reproducibi...mentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, the procedure of MD selection was repeated many times and each time Also, the accuracy of the model (and of the method in general) depends on the set of selected features. Typically, in QSRR works, a set of MD is selected only once [17][18][19][20][21][22] and then the accuracy of the model is carefully investigated (see Fig. 2C) using cross-validation or one-leave-out approaches.…”
Section: Evaluation Of the Molecular Descriptor Selection Reproducibi...mentioning
confidence: 99%
“…QSRR can be considered as a method that provides an insight into chromatographic separation [16]. When predicting a retention index (RI) based on some molecular descriptors (i.e., numerical values that characterize the structure of a molecule), the contribution of particular molecular descriptors (MD) and a set of selected MD can provide valuable information about the nature of separation, and the model is considered as an interpretable one [16][17][18][19][20]. Almost all work on QSRR for GC is limited to the most typical and well-characterized polymeric SP.…”
Section: Introductionmentioning
confidence: 99%