2012
DOI: 10.1002/jssc.201200196
|View full text |Cite
|
Sign up to set email alerts
|

A simple gas chromatography method for the analysis of monoethanolamine in air

Abstract: A simple method determining airborne monoethanolamine has been developed. Monoethanolamine determination has traditionally been difficult due to analytical separation problems. Even in recent sophisticated methods, this difficulty remains as the major issue often resulting in time-consuming sample preparations. Impregnated glass fiber filters were used for sampling. Desorption of monoethanolamine was followed by capillary GC analysis and nitrogen phosphorous selective detection. Separation was achieved using a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 34 publications
0
5
0
Order By: Relevance
“…An improvement in the peak shape of amines in the subsequent GC analysis can be also expected after the derivatization reaction with cyclohexanone. Compared to other techniques reported earlier [4,5], the developed method showed a good sensitivity to gaseous MEA, suggesting a future possibility to real air samples analysis.…”
Section: Discussionmentioning
confidence: 85%
See 2 more Smart Citations
“…An improvement in the peak shape of amines in the subsequent GC analysis can be also expected after the derivatization reaction with cyclohexanone. Compared to other techniques reported earlier [4,5], the developed method showed a good sensitivity to gaseous MEA, suggesting a future possibility to real air samples analysis.…”
Section: Discussionmentioning
confidence: 85%
“…In this work, a fiber-packed sample preparation needle with cyclohexanone, as the derivatization reagent, for simultaneous derivatization/extraction of MEA in air samples, has been developed for the GC analysis. This method only requires very short processing time compared other conventional techniques [4][5][6][7][8][9].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A GC system (Shimadzu GC-2010) equipped with a standard oven for temperature ramping, split condition, injection ports, a flame ionization detector and a Rtx-35 amine column (30 mm × 0.32 mm × 1µm film thickness) in the presence of nitrogen as a carrier gas by the direct injection method was used for the analysis of monoethanolamine (MEA). The analytical parameters for the analysis of MEA are summarized in Table 1, as per the method (by modifying the column and its parameters) reported in the literature [21]. A standard solution of 0.125 to 0.5% v/v MEA (corresponding to ppm and prepared in methanol) was injected along with the processed culture supernatant (1:10, filtrate volume of 1 and 9 volumes of methanol), as per the method described above.…”
Section: Gas Chromatography (Gc) Studies Of Degradation Intermediate(s)mentioning
confidence: 99%
“…The limits of detection (LOD) were 0.5 μg sample −1 for 2PG1BE, EGBE, DEGEE, DEGBE, EGPhE, BA and 1 μg sample −1 for DPGME. Collection and analysis of MEA has been described previously (Gerster et al, 2012). Briefly, impregnated (H 2 SO 4 ) glass fiber filters inserted in the filter holder and attached to an air sampling pump (Air Check XR5000; SKC Inc.) operating at 1 l min −1 was used for collecting airborne MEA.…”
Section: Sampling Strategymentioning
confidence: 99%