2019
DOI: 10.1002/jssc.201900579
|View full text |Cite
|
Sign up to set email alerts
|

A simple two‐stage column chromatographic separation scheme for strontium, lead, neodymium and hafnium isotope analyses in geological samples by thermal ionization mass spectrometry or multi‐collector inductively coupled plasma mass spectrometry

Abstract: Here, a two-stage column separation scheme is developed for the concomitant isolation of Sr, Pb, Nd, and Hf from geological samples. The first column, which consists of three resin layers (AG50W-X8 ion exchange resin + Ln specific resin + Sr specific resin), separates the high field strength element + rare earth element, Sr and Pb from the matrices. Subsequently, Nd and Hf are further separated from the high field strength element + rare earth element fraction on the second column using 1 mL of Ln specific res… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 68 publications
4
9
0
Order By: Relevance
“…Sample preparation and measurement methods followed that of Lei et al. 35 The measured 87 Sr/ 86 Sr ratio was corrected for mass fractionation by normalization to a constant 86 Sr/ 88 Sr ratio of 0.1194 using an exponential law. The isobaric interference of 87 Rb on 87 Sr was corrected using a natural 87 Rb/ 85 Rb ratio of 0.3857.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Sample preparation and measurement methods followed that of Lei et al. 35 The measured 87 Sr/ 86 Sr ratio was corrected for mass fractionation by normalization to a constant 86 Sr/ 88 Sr ratio of 0.1194 using an exponential law. The isobaric interference of 87 Rb on 87 Sr was corrected using a natural 87 Rb/ 85 Rb ratio of 0.3857.…”
Section: Methodsmentioning
confidence: 99%
“…An MC-ICPMS (multiple collector inductively coupled plasma mass spectrometer, Thermo Fisher Neptune) in Nanjing Normal University was used for the Sr isotopic analyses. Sample preparation and measurement methods followed that of Lei et al 35 The measured 87 Sr/ 86 Sr ratio was corrected for mass fractionation by normalization to a constant 86 Sr/ 88 Sr ratio of 0.1194 using an exponential law. The isobaric interference of 87 Rb on 87 Sr was corrected using a natural 87 Rb/ 85 Rb ratio of 0.3857.…”
Section: Provenance Testmentioning
confidence: 99%
“…For conventional Sr and Nd isotope analyses, the sample weight is typically more than 50 mg. [20][21][22][23] To eliminate matrix elements and isobaric interference elements for high-precision isotopic analysis, the purication of Sr and Nd commonly employed two-step, [23][24][25][26] three-step, 21,[27][28][29] or four-step 30 chromatography methods, which are tedious and time-consuming. Furthermore, the complex separation scheme may introduce higher total procedural blanks.…”
Section: Introductionmentioning
confidence: 99%
“…Column chromatography is the most common technique for sample preparation [1][2][3][4][5]. However, traditional manual drip chromatography is tedious and time-consuming.…”
Section: Introductionmentioning
confidence: 99%