2004
DOI: 10.1088/0031-9155/49/15/009
|View full text |Cite
|
Sign up to set email alerts
|

A simplified model of the source channel of the Leksell Gamma Knife®: testing multisource configurations with PENELOPE

Abstract: A simplification of the source channel geometry of the Leksell Gamma Knife , recently proposed by the authors and checked for a single source configuration (Al-Dweri et al 2004), has been used to calculate the dose distributions along the x, y and z axes in a water phantom with a diameter of 160 mm, for different configurations of the Gamma Knife including 201, 150 and 102 unplugged sources. The code PENELOPE (v. 2001) has been used to perform the Monte Carlo simulations. In addition, the output factors for th… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 10 publications
0
16
0
Order By: Relevance
“…1 and 17. PENELOPE has been applied to many different problems [18][19][20][21][22][23][24][25] and has been validated extensively. [26][27][28] PENE-LOPE was adapted to the specific requirements of the MANTIS simulation using PENEASY, a generic main program and accessory routines that allow easy configuration of PENELOPE.…”
Section: Iia Physics Modelsmentioning
confidence: 99%
“…1 and 17. PENELOPE has been applied to many different problems [18][19][20][21][22][23][24][25] and has been validated extensively. [26][27][28] PENE-LOPE was adapted to the specific requirements of the MANTIS simulation using PENEASY, a generic main program and accessory routines that allow easy configuration of PENELOPE.…”
Section: Iia Physics Modelsmentioning
confidence: 99%
“…2 that is published and freely distributed with the PENELOPE code by the Nuclear Energy Agency ͑NEA͒. PENELOPE has been applied to many problems [5][6][7][8][9][10][11][12] and has been validated extensively. [13][14][15] PENELOPE was adapted to the specific requirements of the MANTIS simulation using PENEASY, 42 a generic main program and accessory routines that allow easy configuration of PENELOPE.…”
Section: A Physics Modelsmentioning
confidence: 99%
“…Previously, numerous studies were done to analyze the accuracy of plugging in Gamma Knife 7 , 8 , 9 , 10 . There are a set of Monte Carlo (MC) studies which were successfully used for simulating Gamma Knife sources and units itself, including plugging patterns 2 , 7 , 10 , 11 , 12 , 13 , 14 , 15 . Cheung et al (7) employed Monte Carlo general‐purpose code EGS4 implementing PRESTA (parameter reduced electron‐step transport algorithm) algorithm and GAFCHROMIC films (Type MD 55) 16 , 17 to verify the accuracy of LGP TPS when plugged collimators were used.…”
Section: Introductionmentioning
confidence: 99%