2021
DOI: 10.1039/d1nr02461b
|View full text |Cite
|
Sign up to set email alerts
|

A simplified point-of-care testing approach for preeclampsia blood biomarkers based on nanoscale field effect transistors

Abstract: Rapid diagnosis of preeclampsia is necessary to ensure timely administration of appropriate care and prevent the potentially catastrophic complications of the condition affecting both mothers and babies. While the diagnostic...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(14 citation statements)
references
References 54 publications
0
14
0
Order By: Relevance
“…The dilution factor was taken into consideration when calculating the limit of detection for the nucleocapsid protein in blood. The indium oxide nanoribbon FET sensors were fabricated as previously described and integrated within the 3D-printed fluidic device. , All FET measurements were performed using a Keysight Precision Source/Measure Unit B2900A Series (Keysight Technologies, USA). The data were recorded and interpreted via Keysight EasyEXPERT Software (Keysight Technologies, USA).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The dilution factor was taken into consideration when calculating the limit of detection for the nucleocapsid protein in blood. The indium oxide nanoribbon FET sensors were fabricated as previously described and integrated within the 3D-printed fluidic device. , All FET measurements were performed using a Keysight Precision Source/Measure Unit B2900A Series (Keysight Technologies, USA). The data were recorded and interpreted via Keysight EasyEXPERT Software (Keysight Technologies, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The indium oxide nanoribbon FET sensors were fabricated as previously described and integrated within the 3D-printed fluidic device. 5,6 All FET measurements were performed using a Keysight Precision Source/Measure Unit B2900A Series (Keysight Technologies, USA). The data were recorded and…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
See 2 more Smart Citations
“…In this field, nanotechnology was also applied with different intents: (1) to improve diagnostic management and (2) to implement treatment strategies. New nanotechnology-based point-of-care tests are being developed to improve the assessment of preeclampsia development risk [ 97 , 98 , 99 ]. For instance, recent advancements have been made in the development of electrochemical immunosensors for the early clinical diagnosis of preeclampsia within the 18–20th gestational weeks [ 100 ].…”
Section: Preeclampsia and Fetal Growth Restrictionmentioning
confidence: 99%