2008
DOI: 10.1039/b718597a
|View full text |Cite
|
Sign up to set email alerts
|

A simplified procedure for the determination of stable chlorine isotope ratios (δ37Cl) using LA-MC-ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
52
2
1

Year Published

2008
2008
2020
2020

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 43 publications
(56 citation statements)
references
References 7 publications
1
52
2
1
Order By: Relevance
“…The relatively small overall scatter of 37 Cl/ 35 Cl ratios for all analyses (Spearman's rho = 0.969 for 197 analyses), and the presence of the same types of minerals in both populations (high and low Cl) implies that the ablated mineral species is not responsible for the observed differences in Cl counts. Argon was used as a carrier gas and it stands to reason that the elevated counts for 37 Cl can be attributed to 36 ArH + (Fietzke et al 2008), although in our analyses, this was not quantified. Taking this into consideration, the consistent results obtained point to small, but significant, differences in 37 Cl/ 35 Cl , Cl/Br, and Cl/I ratios between the populations.…”
Section: Halidesmentioning
confidence: 97%
“…The relatively small overall scatter of 37 Cl/ 35 Cl ratios for all analyses (Spearman's rho = 0.969 for 197 analyses), and the presence of the same types of minerals in both populations (high and low Cl) implies that the ablated mineral species is not responsible for the observed differences in Cl counts. Argon was used as a carrier gas and it stands to reason that the elevated counts for 37 Cl can be attributed to 36 ArH + (Fietzke et al 2008), although in our analyses, this was not quantified. Taking this into consideration, the consistent results obtained point to small, but significant, differences in 37 Cl/ 35 Cl , Cl/Br, and Cl/I ratios between the populations.…”
Section: Halidesmentioning
confidence: 97%
“…25,26 In the case of boron isotopes the slope of the linear fit of 11 B plotted against 10 B intensities is used, covering the whole simultaneous signal development for both isotopes from baseline to maximum intensities. The merits of this method when compared to a conventional baseline reduction were already explained in detail in the references mentioned above.…”
Section: Instrumentation Data Acquisition and Evaluationmentioning
confidence: 99%
“…Pyrohydrolysis is a simple alternative for decomposition of organic 7,19,31,33 and inorganic [34][35][36] materials when halogens determination is intended. The main advantages are the possibility of matrix separation and the use of a diluted alkaline solution for analytes absorbing.…”
Section: Introductionmentioning
confidence: 99%