2010
DOI: 10.1021/ac102175z
|View full text |Cite
|
Sign up to set email alerts
|

A Structural Mass Spectrometry Strategy for the Relative Quantitation of Ligands on Mixed Monolayer-Protected Gold Nanoparticles

Abstract: It is becoming increasingly common to use gold nanoparticles (AuNPs) protected by a heterogeneous mixture of thiolate ligands, but many ligand mixtures on AuNPs cannot be properly characterized due to the inherent limitations of commonly used spectroscopic techniques. Using ion mobility-mass spectrometry (IM-MS), we have developed a strategy which allows measurement of the relative quantity of ligands on AuNP surfaces. This strategy is used for the characterization of three samples of mixed-ligand AuNPs: tiopr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
37
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 36 publications
(41 citation statements)
references
References 43 publications
4
37
0
Order By: Relevance
“…30 Also shown is a positive correlation between concentration of PEG in solution and percent coverage; however, no significant gain in percent coverage was noted until larger PEG feed ratios were used. At lower feed ratios, the loading percentage difference between 10:1 and 15:1 was minimal.…”
Section: Resultsmentioning
confidence: 96%
See 2 more Smart Citations
“…30 Also shown is a positive correlation between concentration of PEG in solution and percent coverage; however, no significant gain in percent coverage was noted until larger PEG feed ratios were used. At lower feed ratios, the loading percentage difference between 10:1 and 15:1 was minimal.…”
Section: Resultsmentioning
confidence: 96%
“…In keeping with our previous experiments, 30 1% relative abundance and 30 ppm mass accuracy cutoffs were used to reduce false positive identifications, and the monoisotopic ion abundances for the identified peaks were normalized to the expected monoisotopic abundance for each respective ion. The final set of identified peaks was used in quantitation calculations by the application of Eqn.…”
Section: Ion Mobility-mass Spectrometrymentioning
confidence: 99%
See 1 more Smart Citation
“…In this context, MALDI-Ion Mobility-MS [70] allowed to measure the relative quantity of ligands on a given AuNPs surface. The results were successfully validated by nuclear magnetic resonance (NMR) spectroscopy and by MS without ion mobility separation (in fact, average differences of less than 1% relative abundance were reported).…”
Section: Matrix-assisted Laser Desorption/ionizationmentioning
confidence: 99%
“…Since then, MS has been widely adopted in almost all the structural analysis of metal NPs. So far various MS techniques such as MALDI-TOF MS [28,43,44,55,56], ESI-MS [57,58], LDI-MS [59], ion mobility MS [60,61] and fast atom bombardment MS [62] have been applied to explore the metal core mass of all kinds of metal NPs. Among them, MALDI-TOF MS is the most popular MS technique in determining the number of metal atom of NP fractions.…”
Section: Mass Spectrometric Analysis Of Dmf-pdnps Fractionsmentioning
confidence: 99%