2012
DOI: 10.3938/jkps.60.1177
|View full text |Cite
|
Sign up to set email alerts
|

A study on concentration measurements of radon-222 (uranium series) and radon-220 (thoron series) emitted to the atmosphere from tex (cementitious), red brick, and ecocarat among construction materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…Measurement of radioactive substances in water, soil and air are done in various ways, such as alpha spectrophotometry, inductively coupled plasma/mass spectrophotometer, gamma spectrophotometry and liquid Scintillation (Rožmarić, Rogi, Benedik, & Štrok, 2012). Recently, many studies measure the concentration of 222 Rn portable devices, such as RAD7 RTM ( Mehra and Bala, 2013 ; Ju, Ryu, Jang, Dong, & Chung, 2012 ; Todorovic, Jovana Nikolov, Sofija Forkapic, Istvan Bikit, & Dusan Mrdja, 2012 ; Lee & Kim, 2006 ). Hence, in this study a model of portable alpha spectrophotometry RTM1688-2 was used to measure 222 Rn in drinking water.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Measurement of radioactive substances in water, soil and air are done in various ways, such as alpha spectrophotometry, inductively coupled plasma/mass spectrophotometer, gamma spectrophotometry and liquid Scintillation (Rožmarić, Rogi, Benedik, & Štrok, 2012). Recently, many studies measure the concentration of 222 Rn portable devices, such as RAD7 RTM ( Mehra and Bala, 2013 ; Ju, Ryu, Jang, Dong, & Chung, 2012 ; Todorovic, Jovana Nikolov, Sofija Forkapic, Istvan Bikit, & Dusan Mrdja, 2012 ; Lee & Kim, 2006 ). Hence, in this study a model of portable alpha spectrophotometry RTM1688-2 was used to measure 222 Rn in drinking water.…”
Section: Methodsmentioning
confidence: 99%
“…According to measurement of 300 mL, after the sample size reached the intended temperature, the device was placed in a closed cycle ( Figure 2 ). The time for balance between concentration of 222 Rn and its decay products (daughters 222 Rn) is 4 hour approximately ( Ju, Ryu, & Jang, 2012 ; Mehra & Bala, 2013 ; Lee & Kim, 2006 ). Hence, the 4 hour mean concentration of 222 Rn (Bq/l) and the initial temperature (ºC) was recorded.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation