2022 44th Annual International Conference of the IEEE Engineering in Medicine &Amp; Biology Society (EMBC) 2022
DOI: 10.1109/embc48229.2022.9870980
|View full text |Cite
|
Sign up to set email alerts
|

A System-on-Board Integrated Multi-analyte PoC Biosensor for Combined Analysis of Saliva and Exhaled Breath

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…After aptamer immobilization, the non-specific binding sites in some papers were blocked with BSA, EA, or mercaptoethanol (2ME). Other papers did not report such a blockage step [1], [4], [69], [70], [74], [75], [76], [77], [78], [81], [82], [83].…”
Section: C1 Sensor Structurementioning
confidence: 99%
See 1 more Smart Citation
“…After aptamer immobilization, the non-specific binding sites in some papers were blocked with BSA, EA, or mercaptoethanol (2ME). Other papers did not report such a blockage step [1], [4], [69], [70], [74], [75], [76], [77], [78], [81], [82], [83].…”
Section: C1 Sensor Structurementioning
confidence: 99%
“…Redox probes were generally not used in sensors that relied on the EIS technique for the sensor readout [4], [69], where the system was shown to become increasingly capacitive with increasing cortisol concentration. Similar to the FET-based immunosensors, the FET-based aptasensors allowed label-free detection as well [1], [77], [78], [80], [81], [82], [83]. Notably, it was shown in [70] that the addition of metalloporphyrin on the working electrode can catalyze the electrochemical reduction of cortisol, allowing redox probe-free measurement.…”
Section: C2 Electrochemical Modality and Label-free Detectionmentioning
confidence: 99%
“…Furthermore, the sensor can be easily interfaced with off-the-shelf portable EIS readers, making it point-of-care ready. Previously, we reported a MIP EIS sensor integrated with a PCB for portable and quantitative analysis of 8-Isoprostane in exhaled breadth [14]. Similarly, integrating the proposed SIP EIS is being adopted in the next phase of platform testing and validation.…”
Section: Preliminary Data From Microfluidic Channel Sip Eis Biosensormentioning
confidence: 99%
“…As an alternative to electrochemical and electrolyte-gated biosensors, electroimpedance spectroscopy (EIS) sensors transduce sample target biomarker binding by measuring the change of reactance and resistance as a function of angular frequency [13]. EIS is capable of rapid, non-destructive, label-free characterization without current production to perform measurements [14]. EIS is highly sensitive to near-surface effects, making it ideal for affinity biosensors, with a simple electrode design requiring only interdigitated structures of counter and reference electrodes.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation