2004
DOI: 10.1023/b:janc.0000011668.20677.d1
|View full text |Cite
|
Sign up to set email alerts
|

A Thermal-Desorption Surface-Ionization Indicator of Narcotics and Other Drug Preparations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
5

Year Published

2005
2005
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(14 citation statements)
references
References 5 publications
0
8
0
5
Order By: Relevance
“…The geometry and dimensions of the SI ion source correspond to that of thermal desorption surface-ionization spectrometer. 28,29 The thermoemitter is made of a single crystal of molybdenum doped with iridium in the form of a hollow cylinder, that is oxidized according to the procedure. 28 The thermoemitter temperature was within the range 650-700 K. The skimmer of the SCIEX-API-III spectrometer was located at a distance corresponding to the ion detection plane.…”
Section: Methodsmentioning
confidence: 99%
“…The geometry and dimensions of the SI ion source correspond to that of thermal desorption surface-ionization spectrometer. 28,29 The thermoemitter is made of a single crystal of molybdenum doped with iridium in the form of a hollow cylinder, that is oxidized according to the procedure. 28 The thermoemitter temperature was within the range 650-700 K. The skimmer of the SCIEX-API-III spectrometer was located at a distance corresponding to the ion detection plane.…”
Section: Methodsmentioning
confidence: 99%
“…A modernized device "IK-Iskovich" was used to study synthetic cannabinoides by TDТIS [6,7]. Briefly, the device consists of a temperature-programmed evaporator of the compound samples under analysis and a TI triode detector through which air moves from the evaporator to the detector.…”
Section: Ii1 the Device And Experimental Conditionsmentioning
confidence: 99%
“…Evaporated from the band, the sample molecules move with airflow to the surface ionization detector where the molecules are ionized by SI. This device "Iskovich-1" is different from [6,10,11] by connecting with a PC and having a database of thermodesorption spectra of psychotropic preparations and calibration curves. In experiments, the emitter temperature was 700 K, air velocity 50 L/h, evaporator temperature scanning from a room temperature to 500 • C with a linear rate of 10 K/s.…”
Section: Instrumentmentioning
confidence: 99%
“…For the intermediate concentration in the thermodesorption spectra, there are both peaks. Such a character of the dependence can be explained by a difference in the values of sublimation and desorption heat of the molecules from the evaporator surface [10,11]. For the great amount of the substance, molecule evaporation is defined by sublimation heat; for the small amount of the substance, all the molecule are adsorbed on the evaporator surface, and to be evaporated they have to overcome energy of desorption activation.…”
Section: Atmosphere-pressure Thermodesorption Surface Ionization Specmentioning
confidence: 99%
See 1 more Smart Citation