2011
DOI: 10.1016/j.jpowsour.2010.12.088
|View full text |Cite
|
Sign up to set email alerts
|

A thermophilic microbial fuel cell design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
16
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(18 citation statements)
references
References 20 publications
2
16
0
Order By: Relevance
“…The main drawback reported in BESs operating at temperatures higher than 50 °C is electrolyte evaporation. An increase in salt concentration and metabolites as well as cell debris which consequently hampered the microbial activity in these BESs has been reported for these operating temperatures …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The main drawback reported in BESs operating at temperatures higher than 50 °C is electrolyte evaporation. An increase in salt concentration and metabolites as well as cell debris which consequently hampered the microbial activity in these BESs has been reported for these operating temperatures …”
Section: Introductionmentioning
confidence: 99%
“…An increase in salt concentration and metabolites as well as cell debris which consequently hampered the microbial activity in these BESs has been reported for these operating temperatures. 23 Until now all studies on MES have been performed at mesophilic conditions 6,9 and an evaluation of the performance of MES for the production of multi-carbon molecules at elevated temperatures and the effect of temperature on rate and efficiency is currently lacking. Production of methane at higher temperatures using electric current has recently been described.…”
Section: Introductionmentioning
confidence: 99%
“…But researches showed that the thermophilic metabolism has advantages than the mesophilic metabolism. Sarah M. Carver stated the thermophilic condition for wastewater anaerobic digester improved efficiency, and removed many human and animal pathogens (Carvera et al 2011). It seems operation in thermophilic condition may be useful for improvement of effluent quality.…”
Section: Resultsmentioning
confidence: 99%
“…However, a negative point of thermophilic MFCs is higher rates of evaporation than the MFC system itself. Therefore, a continuous mode of MFCs was proposed to allow a replacement of the anolyte and catholyte [79].…”
Section: Psychrophiles and Thermophilesmentioning
confidence: 99%