2007
DOI: 10.1016/j.jasms.2006.09.011
|View full text |Cite
|
Sign up to set email alerts
|

A triaxial probe for on-line proteolysis coupled with hydrogen/deuterium exchange-electrospray mass spectrometry

Abstract: An on-line proteolysis system utilizing a triaxial electrospray probe was developed to aid localization of the hydrogen-bonding interaction sites in hydrogen/deuterium exchange-mass spectrometry (HDX-MS) studies of A␤ (1-40) fibrils. The probe allows delayed introduction of the organic solvent component needed for stable electrospray, thus enhancing hydrolysis performance relative to that of a coaxial probe. Effective on-line digestion was accomplished in ϳ12 s. The probe should be of general utility for HDX-M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
21
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(24 citation statements)
references
References 38 publications
3
21
0
Order By: Relevance
“…The standard Q-Star IonSpray™ probe can be used in both a triaxial and a coaxial mode; details of these modes are provided elsewhere [19]. Diameters and flows for the various tubes were as indicated in Table 1.…”
Section: Electrospray Mass Spectrometrymentioning
confidence: 99%
See 3 more Smart Citations
“…The standard Q-Star IonSpray™ probe can be used in both a triaxial and a coaxial mode; details of these modes are provided elsewhere [19]. Diameters and flows for the various tubes were as indicated in Table 1.…”
Section: Electrospray Mass Spectrometrymentioning
confidence: 99%
“…Indicated uncertainties in relative intensities (or derived quantities) represent the standard deviation of 3 replicate spectra, each of which comprised 60 scans. To avoid interference from atmospheric moisture in hydrogen/deuterium exchange studies [19], the hole from the source leading to the venturi pump is generally blocked with a rubber stopper and nitrogen gas (500 mL/min, from boil-off) introduced into the source through the "make-up" hole in the source housing during and for 4 hours before sample injection. Although oxidation did not appear to be affected, this precaution was practiced here for consistency with earlier studies.…”
Section: Electrospray Mass Spectrometrymentioning
confidence: 99%
See 2 more Smart Citations
“…However, the long sample incubation times required for trypsin digestion in solution and the extensive sample treatment steps result in long protein processing times. To overcome those obstacles, rapid in-solution digestion protocols have been developed using organic solvents to denature proteins or by applying higher incubation temperature to accelerate reaction time [27][28][29][30]. However, efficient protein identifi-…”
mentioning
confidence: 99%