A Two-accelerator Facility and Its Use for Radiation Damage Studies in Alkali Halides

Abstract: An experimental system is described in which heavy ions of energies 50-100 MeV, and light ions of energies 0·5-2 MeV, may be transported alternatively from different accelerators into a common scattering chamber. Details are given of the beam transport and ~ttering chamber, the latter being designed to make in-beam studies of different modes of radiation damage in the target material. An on-line experimental control and data acquisition system with an IBM 1800 computer is used. Experimental studies are describ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

1987
1987
2000
2000

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…Exarhos (1982) observed the opposite situation for CaF 2 electron irradiated at comparably high doses: the spectral results are similar to NaCl, in which the formation of colloidal particles predominates. Based on the experimental data from α-irradiated NaCl crystals, the chance of F centers recombining with H centers at such high doses is very likely Hay 1980, Newton andHay 1979). When rock salts were exposed to high doses (~10 9 Gy) of γ radiation, the concentration of chlorine measured was only 0.1Êppm (Jockwer and Mšnig 1989).…”
Section: Formation and Detection Of Metal Colloids And Chloride Speciesmentioning
confidence: 99%
“…Exarhos (1982) observed the opposite situation for CaF 2 electron irradiated at comparably high doses: the spectral results are similar to NaCl, in which the formation of colloidal particles predominates. Based on the experimental data from α-irradiated NaCl crystals, the chance of F centers recombining with H centers at such high doses is very likely Hay 1980, Newton andHay 1979). When rock salts were exposed to high doses (~10 9 Gy) of γ radiation, the concentration of chlorine measured was only 0.1Êppm (Jockwer and Mšnig 1989).…”
Section: Formation and Detection Of Metal Colloids And Chloride Speciesmentioning
confidence: 99%
“…The equipment and methods used for PIXE have been described by Newton and Hay (1980). Experience has shown that it is straightforward, but time-consuming, to maintain stability of the proton accelerator, the X-ray detector and associated electronics and to keep them calibrated to within 2%.…”
Section: Experimental Methodsmentioning
confidence: 99%