A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate‐512

Abstract: The response of the 2D detector array, MP512, has been evaluated. The properties of the array demonstrated suitability for use as in phantom dosimeter for QA in SRS and SBRT. Although MP512 matches film measurements down to 1×1 cm2 well, it showed a discrepancy of 4% in the determination of output factors of beams smaller than 0.5×0.5 cm2 due to the field perturbation generated by the large amount of silicon surrounding the central diode. MP512 is highly capable of measuring beam size (FWHM) and has a discrepa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
69
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 48 publications
(73 citation statements)
references
References 41 publications
4
69
0
Order By: Relevance
“…DUO array was irradiated up to 140 kGy in steps of 20 kGy. During irradiation, temperature was kept constant at 30 °C and no bias applied, respectively [13]. When a linac with photon energy higher than 10 MV is used, neutrons are produced by photons interacting with high-Z material located in the linac head (primary collimators, jaws, flattening filter) [25][26] [27] and any other material surrounding the beam.…”
Section: G Radiation Damagementioning
confidence: 99%
See 3 more Smart Citations
“…DUO array was irradiated up to 140 kGy in steps of 20 kGy. During irradiation, temperature was kept constant at 30 °C and no bias applied, respectively [13]. When a linac with photon energy higher than 10 MV is used, neutrons are produced by photons interacting with high-Z material located in the linac head (primary collimators, jaws, flattening filter) [25][26] [27] and any other material surrounding the beam.…”
Section: G Radiation Damagementioning
confidence: 99%
“…A total dose of 100 cGy has been delivered to achieve a good signal to noise ratio in the film measurements. The film analysis performed in this study is the same adopted by Aldosari et al [13]. Full width at half maximum (FWHM) and 20%-80% studies of the penumbra were performed and compared against the reference EBT3 film.…”
Section: H Charge Collection Efficiency Charge Sharing and Spatial Rementioning
confidence: 99%
See 2 more Smart Citations
“…The addition of either a second orthogonal array of SV's or a complete 2D array of SV's would also allow for concurrent measurement of point dose and orthogonal beam profiles (or the entire beam profile in the case of a 2D array), which would provide further QA information in pencil beam scanning applications where the size and shape of the proton beam also need to be evaluated. The feasibility of this approach was recently demonstrated by the CMRP in development, characterization, and application of a 2D monolithic silicon pixel array (with submillimeter SVs and a pitch of 2 mm) in dose mapping on a medical linac 26, 27…”
Section: Discussionmentioning
confidence: 99%