2021
DOI: 10.1109/tim.2021.3085970
|View full text |Cite
|
Sign up to set email alerts
|

A Wireless, Low-Power, and Miniaturized EIT System for Remote and Long-Term Monitoring of Lung Ventilation in the Isolation Ward of ICU

Abstract: Individualized lung-protective ventilation strategy is essential for patients with COVID-19. In this study, a wireless, low-power and miniaturized electrical impedance tomography (EIT) system was developed for remote and long-term monitoring of lung ventilation for patients with COVID-19 in the isolation ward of ICU. A new strategy of combining filtering and improved voltage-controlled current was employed to design the current source for a simplified system structure, and a new differential receiver circuit c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 41 publications
0
9
0
Order By: Relevance
“…Second, for convenient use, it is best to integrate the impedance system into a chip or a circuit board to further reduce its size to embed it into the measurement module. Third, a small excitation current should be explored (1 mA was used in the present study) whether it could also obtain reliable measurements to evaluate LBP, so that a battery of small size can be used as power supply to further minimize the impedance system ( Yang et al, 2021 ).…”
Section: Discussionmentioning
confidence: 99%
“…Second, for convenient use, it is best to integrate the impedance system into a chip or a circuit board to further reduce its size to embed it into the measurement module. Third, a small excitation current should be explored (1 mA was used in the present study) whether it could also obtain reliable measurements to evaluate LBP, so that a battery of small size can be used as power supply to further minimize the impedance system ( Yang et al, 2021 ).…”
Section: Discussionmentioning
confidence: 99%
“…Reducing the size and the number of cables is essential. Some EIT devices digitalize the voltage signals directly at the electrodes so that the cable connecting the subject and the monitor is minimized, whereas the other devices might use wireless connection to avoid any connection cables [13]. Nevertheless, for EIT systems that equips with reference electrode, it is important to ensure the proper contact and functionality of the reference electrode.…”
Section: Discussionmentioning
confidence: 99%
“…The implementation of the mesh phantoms [17], [30]- [39] requires a meticulous handcrafting design of the PCB layout. Thus, we propose the following PCB design automation for the mesh phantom: (i) contour construction of the mesh phantom, (ii) placement and routing of resistors, and (iii) implementation of dynamic mesh phantom.…”
Section: Design Automation Of the Mesh Phantom On Printed Circuit Boa...mentioning
confidence: 99%
“…The phantoms are generally classified into (i) physical phantoms [15], [21]- [29], and (ii) mesh phantoms [17], [30]- [39]. (i) Physical phantoms are implemented using a container filled with a conductive medium, usually saline water [15], [23], [24], [26], [27], [29].…”
Section: Introductionmentioning
confidence: 99%