2021
DOI: 10.1002/mp.14992
|View full text |Cite
|
Sign up to set email alerts
|

AAPM Task Group 198 Report: An implementation guide for TG 142 quality assurance of medical accelerators

Abstract: The charges on this task group (TG) were as follows: (a) provide specific procedural guidelines for performing the tests recommended in TG 142; (b) provide estimate of the range of time, appropriate personnel, and qualifications necessary to complete the tests in TG 142; and (c) provide sample daily, weekly, monthly, or annual quality assurance (QA) forms. Many of the guidelines in this report are drawn from the literature and are included in the references. When literature was not available, specific test met… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
47
0
16

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 95 publications
(88 citation statements)
references
References 133 publications
(324 reference statements)
2
47
0
16
Order By: Relevance
“…In linac QA, one of the many critical parameters which must be monitored is the stability of the mechanical isocentre ( 4 ). It is well established that imperfections in linac gantry rotation caused by the strong pull of gravity lead to slight deviations to the isocentre during treatment delivery.…”
Section: Introductionmentioning
confidence: 99%
“…In linac QA, one of the many critical parameters which must be monitored is the stability of the mechanical isocentre ( 4 ). It is well established that imperfections in linac gantry rotation caused by the strong pull of gravity lead to slight deviations to the isocentre during treatment delivery.…”
Section: Introductionmentioning
confidence: 99%
“…The analysis parameters of leaf position errors were maximum leaf RMS error, 95th percentile error, the number of failed leaves and the percentage of different leaf positioning errors. The first two analysis parameters are recommended in the TG-142 and TG-198 report, and the report believes that these two parameters are helpful for analyzing the state of the MLC performance [ 12 , 13 ]. The maximum leaf RMS error is a single value, which is the maximum RMS error of all leaves in bank A and bank B.…”
Section: Methodsmentioning
confidence: 99%
“…The TG-51 recommends a tolerance of 0.5 mm for static MLC leaf position accuracy, and the values of the maximum leaf root mean square (RMS) and 95th percentile leaf positioning error were not proposed [ 11 ]. In TG-142 and the latest TG-198, the tolerance of MLC leaf position accuracy is ± 1 mm, and the RMS and 95th percentile errors should be < 0.35 cm [ 12 , 13 ]. The above guidelines recommended annual assessments for the both tests.…”
Section: Introductionmentioning
confidence: 99%
“…Volumetric modulated arc therapy and multiple gantry angle intensity‐modulated radiotherapy are commonly utilized in modern radiotherapy departments, and the requirement for an accurate multi‐leaf collimator (MLC) in these techniques is well documented. [ 1–3 ] Multiple professional guidelines and publications recommend completing MLC quality assurance (QA) at multiple gantry angles to ensure the MLC performance is maintained over the full range of rotational motion. [ 2–6 ]…”
Section: Introductionmentioning
confidence: 99%
“…Volumetric modulated arc therapy and multiple gantry angle intensity-modulated radiotherapy are commonly utilized in modern radiotherapy departments, and the requirement for an accurate multi-leaf collimator (MLC) in these techniques is well documented. [1][2][3] Multiple professional guidelines and publications recommend completing MLC quality assurance (QA) at multiple gantry angles to ensure the MLC performance is maintained over the full range of rotational motion. [2][3][4][5][6] Most modern linacs are fitted with an electronic portal imaging device (EPID) that can produce images from the megavoltage (MV) beam and are an efficient tool for tasks such as MLC QA and patient-specific quality assurance (PSQA).…”
Section: Introductionmentioning
confidence: 99%