“…The results showed that an optimal separation with the best sensitivity was obtained with water/methanol/acetic acid (94/5/1, v / v / v (A)) and methanol/water/acetic acid (97/2/1, v / v / v (B)), both adjusted with 5 mM ammonium acetate. These results are in accordance with previously reported LC-MS/MS methods for multi-mycotoxin analysis [ 40 ].…”
Section: Resultssupporting
confidence: 93%
See 1 more Smart Citation
“…The results showed that an optimal separation with the best sensitivity was obtained with water/methanol/acetic acid (94/5/1, v / v / v (A)) and methanol/water/acetic acid (97/2/1, v / v / v (B)), both adjusted with 5 mM ammonium acetate. These results are in accordance with previously reported LC-MS/MS methods for multi-mycotoxin analysis [ 40 ].…”
Section: Resultssupporting
confidence: 93%
“…The two most intense product ions were selected for the MRM transitions of the MS method after applying different collision energies ( Table 1 ). Based on previous studies carried out in the same laboratory [ 24 , 39 , 40 ], an Acquity UPLC ® HSS T3 [1.8 µm, 2.1 mm × 100 mm] chromatographic column was chosen, demonstrating proper retention times for all the analyzed mycotoxins. Different mobile phases for an optimal separation, including mixtures of water with a volatile organic acid or ammonium acetate with an organic solvent (methanol) were tested [ 24 , 41 ].…”
Section: Resultsmentioning
confidence: 99%
“…The materials used were gelatin as extracellular matrix and titanium oxide and silver nanoparticles. The device can measure in vitro contractile effects by cardiotoxicity of nanoparticles that affect calcium signal to sarcomere [ 108 ]. Cardiomyocytes clusters in spheroid geometry are part of an experiment for drug testing in a microfluidic device.…”
Section: Microfluidic: Organ-on-a-chipmentioning
confidence: 99%
“…Concerning the reaction format, the single-step synthetic route was applied, which was not only simple and fast but also generated super-porosity for the selectivity of monolith [23]. Therefore, the optimization factors of the ratio of the template/functional monomer/cross-linker, the reaction time and the reaction temperature were investigated in the preparation of the molecularly imprinted monolith [24,25].…”
Section: Preparation Of the Molecularly Imprinted Monolithmentioning