1978
DOI: 10.1016/0022-4073(78)90091-2
|View full text |Cite
|
Sign up to set email alerts
|

Absolute intensity measurements at different temperatures of the C12O216 bands 30°1I←0000 and 30°1IV←0000

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
11
0

Year Published

1986
1986
2010
2010

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 8 publications
2
11
0
Order By: Relevance
“…Fourier transform spectra recorded at 197, 233 and 294 K were used to study the temperature dependence of 22 self-broadened transitions in each of the 30013'00001 [5] and 30012'00001 [6] vibrational bands. The absolute line intensities, self-and foreign-gas broadened line parameters were retrieved using a Voigt profile.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Fourier transform spectra recorded at 197, 233 and 294 K were used to study the temperature dependence of 22 self-broadened transitions in each of the 30013'00001 [5] and 30012'00001 [6] vibrational bands. The absolute line intensities, self-and foreign-gas broadened line parameters were retrieved using a Voigt profile.…”
Section: Introductionmentioning
confidence: 99%
“…There have been very few studies on the temperature dependence of self broadening coefficients in carbon dioxide [5][6][7][8][9][10][11]. Fourier transform spectra recorded at 197, 233 and 294 K were used to study the temperature dependence of 22 self-broadened transitions in each of the 30013'00001 [5] and 30012'00001 [6] vibrational bands.…”
Section: Introductionmentioning
confidence: 99%
“…Toth et al [4] measured the four bands of this Fermi-tetrad by a grating spectrometer, and Suárez and Valero [5][6][7] also observed the same bands by an FTIR spectrometer. Their results carry large experimental error of several percent, and there are systematical difference between the two.…”
Section: Introductionmentioning
confidence: 88%
“…It should be noted that the uncertainties for the present values do not contain the possible errors due to the pressure uncertainty, which may be 0.5% at most. Suárez and Valero [5][6][7] have observed four Fermitetrad bands by an FTIR spectrometer. Their S values are similar to the recent laser study by Pouchet et al [10] who have observed the m 1 + 4m 2 + m 3 band by a diode laser spectrometer.…”
Section: Linestrength Smentioning
confidence: 96%
“…Energy level values were reinvestigated recently by Miller and Brown [5], leading to very accurate absolute line positions (uncertainty 6 · 10 À5 cm À1 ) now available from HITRAN [3]. Individual line intensities in the cold bands were primarily measured by Toth et al [6], and reinvestigated by Suárez and Valero [7][8][9]. Intensities of R-branch lines, and of small J P-branch lines, in the 30012-00001 band, were then obtained by Henningsen and Simonsen [10] by tunable diode laser spectroscopy (TDLS).…”
Section: Introductionmentioning
confidence: 97%