2015
DOI: 10.1007/s11356-015-5192-1
|View full text |Cite
|
Sign up to set email alerts
|

Accelerated solvent extraction (ASE) for purification and extraction of silicone passive samplers used for the monitoring of organic pollutants

Abstract: Silicone passive samplers have gained an increasing attention as single-phased, practical and robust samplers for monitoring of organic contaminants in the aquatic environment in recent years. However, analytical challenges arise in routine application during the extraction of analytes as silicone oligomers are co-extracted and interfere severely during chemical analyses (e.g. gas chromatographic techniques). In this study, we present a fast, practical pre-cleaning method for silicone passive samplers applying… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 8 publications
0
8
0
Order By: Relevance
“…[299] [306,307] Calibration tank Various SR-water partition coefficients were determined for various HOCs through cosolvent methods (water/methanol) and compared to log Kow. [14,217] Calibration tank PAHs; PCBs; pesticides Calculation of new, and recalculation of reported, polymer water partition coefficients for SPMD and SR, through cosolvent, lipid and aqueous exposures in batch experiments, to facilitate conversion of equivalent analyte concentrations between phases with only partition coefficients.…”
Section: Coastal Watersmentioning
confidence: 99%
“…[299] [306,307] Calibration tank Various SR-water partition coefficients were determined for various HOCs through cosolvent methods (water/methanol) and compared to log Kow. [14,217] Calibration tank PAHs; PCBs; pesticides Calculation of new, and recalculation of reported, polymer water partition coefficients for SPMD and SR, through cosolvent, lipid and aqueous exposures in batch experiments, to facilitate conversion of equivalent analyte concentrations between phases with only partition coefficients.…”
Section: Coastal Watersmentioning
confidence: 99%
“…There are various kinds of non-polar passive samplers, which have been used for evaluating organic contaminants in aquatic environments (Brockmeyer et al 2015 ). Passive samplers trap the pollutants in a kinetic or equilibrium diffusion, in which the whole process including selective analyte, isolation, and pre-concentration occurs simultaneously (Vrana et al 2005 ).…”
Section: Introductionmentioning
confidence: 99%
“…A raw silicone sampler contains oligomers that will likely interfere during the post-deployment analysis [ 33 , 34 , 35 ]. Indeed, in a study by Rusina et al [ 29 ], the release of oligomers after exhaustive extraction with ethyl acetate for ten silicone rubbers was tested.…”
Section: Pdms As a Sampler Materialsmentioning
confidence: 99%