2017
DOI: 10.1016/j.bios.2017.06.006
|View full text |Cite
|
Sign up to set email alerts
|

Accelerating bacterial growth detection and antimicrobial susceptibility assessment in integrated picoliter droplet platform

Abstract: There remains an urgent need for rapid diagnostic methods that can evaluate antibiotic resistance for pathogenic bacteria in order to deliver targeted antibiotic treatments. Toward this end, we present a rapid and integrated single-cell biosensing platform, termed dropFAST, for bacterial growth detection and antimicrobial susceptibility assessment. DropFAST utilizes a rapid resazurin-based fluorescent growth assay coupled with stochastic confinement of bacteria in 20 pL droplets to detect signal from growing b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
113
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 119 publications
(113 citation statements)
references
References 42 publications
(46 reference statements)
0
113
0
Order By: Relevance
“…Following on-chip incubation, droplets can be detected sequentially in continuous flow by creating a constriction in the delay line where only a single droplet may pass through at a time. Kaushik and Hsieh et al utilized an on-chip delay line with a detection constriction for individually interrogating droplets during continuous-flow operation (Kaushik et al, 2017). In this work, the microfluidic device was directly connected to supporting instrumentation, which consisted of a Peltier heating device, an optical excitation source and a fluorescence detector (Figure 3Cii).…”
Section: Microfluidic Platforms For Sample Discretizationmentioning
confidence: 99%
See 4 more Smart Citations
“…Following on-chip incubation, droplets can be detected sequentially in continuous flow by creating a constriction in the delay line where only a single droplet may pass through at a time. Kaushik and Hsieh et al utilized an on-chip delay line with a detection constriction for individually interrogating droplets during continuous-flow operation (Kaushik et al, 2017). In this work, the microfluidic device was directly connected to supporting instrumentation, which consisted of a Peltier heating device, an optical excitation source and a fluorescence detector (Figure 3Cii).…”
Section: Microfluidic Platforms For Sample Discretizationmentioning
confidence: 99%
“…In that work, a slightly larger droplet volume (4 nL) required 7.5 h off-chip incubation in order to determine the susceptibility and resistance to methicillin. A rapid and integrated approach was presented by Kaushik and Hsieh et al (Kaushik et al, 2017). Here, the authors encapsulated single bacteria in significantly smaller droplets that are 20 pL in volume.…”
Section: Detection and Screening Of Single-cell Derived Biomarkersmentioning
confidence: 99%
See 3 more Smart Citations