2008
DOI: 10.1111/j.1399-6576.2008.01799.x
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy and reliability of continuous blood glucose monitor in post‐surgical patients

Abstract: Background: The STG‐22™ is the only continuous blood glucose monitoring system currently available. The aim of this study is to determine the accuracy and reliability of the STG‐22™ for continuously monitoring blood glucose level in post‐surgical patients. Methods: Fifty patients scheduled for routine surgery were studied in surgical intensive care unit (ICU) of a university hospital. After admission to the ICU, the STG‐22™ was connected to the patients. An attending physician obtained blood samples from a r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
40
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 54 publications
(45 citation statements)
references
References 19 publications
5
40
0
Order By: Relevance
“…The multichannel pump and the glucose sensor electrode both had an accuracy of !5%. The accuracy and reliability of this system during and after surgery have been confirmed (15,16). In this study, the results using STG-55 were similar to those obtained with the conventional artificial pancreas (STG-22).…”
Section: Discussionsupporting
confidence: 75%
“…The multichannel pump and the glucose sensor electrode both had an accuracy of !5%. The accuracy and reliability of this system during and after surgery have been confirmed (15,16). In this study, the results using STG-55 were similar to those obtained with the conventional artificial pancreas (STG-22).…”
Section: Discussionsupporting
confidence: 75%
“…STG-22 is capable of measuring the blood glucose level continuously with its glucose sensor, and automatically infuses insulin and/or glucose to adjust the blood glucose level in accordance with a target glucose value, which is called a closed-loop system. The perioperative accuracy and reliability of continuous blood glucose monitoring during use of an artificial pancreas have been established, both intraoperatively (21) and postoperatively (22). In this case, STG-22 was shown to be safe and efficient in a patient with insulinoma during and after surgery, similarly to other reports.…”
Section: Discussionsupporting
confidence: 58%
“…The STG-22 system is a reliable and accurate device that measures blood glucose concentrations continuously and is comparable to the ABL 800FLEX machine (Radiometer Medical ApS, Brønshøj, Denmark) recommended by the National Committee for Clinical Laboratory Standards [22,23] . The STG-22 closed-loop glycemic control system is composed of a glucose sensor for the detection and/or monitoring of glucose and pumps for the infusion of appropriate amounts of insulin or glucose [24,25] .…”
Section: Novel Insulin Therapy Using a Closed-loop Artificial Endocrimentioning