Accuracy Evaluation of Five Blood Glucose Monitoring Systems Obtained from the Pharmacy: A European Multicenter Study with 453 Subjects

Abstract: Background: This multicenter study was conducted to evaluate the performance of five recently introduced blood glucose (BG) monitoring (BGM) Ò [Bayer Vital GmbH, Leverkusen, Germany]) in a daily routine setting. All devices and strips were purchased from local regular distribution sources (pharmacies, four strip lots per device). The patients performed the finger prick and the glucose measurement on their own. In parallel, a healthcare professional performed the glucose assessment with the reference method (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
67
3
2

Year Published

2012
2012
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 80 publications
(77 citation statements)
references
References 8 publications
5
67
3
2
Order By: Relevance
“…One study of test-strip accuracy compared 7 meters and tested 3 teststrip lots for each range and found that lot-to-lot variations were as high as 11% using the same meter (158). Another study found that the difference in bias between widely used BGM devices was as high as 4.8% (159). Underfilling the test strip can introduce errors >20% in some BGMs.…”
Section: What Impacts Accuracy?mentioning
confidence: 99%
“…One study of test-strip accuracy compared 7 meters and tested 3 teststrip lots for each range and found that lot-to-lot variations were as high as 11% using the same meter (158). Another study found that the difference in bias between widely used BGM devices was as high as 4.8% (159). Underfilling the test strip can introduce errors >20% in some BGMs.…”
Section: What Impacts Accuracy?mentioning
confidence: 99%
“…[10][11][12][13][14] Within the boundaries of this standard, meters can have very different performance profiles and error patterns.…”
Section: Discussionmentioning
confidence: 99%
“…This study investigated the measurement performance of five BGM systems independently obtained from pharmacies 10 and analyzed a total of 453 patients (T1DM or T2DM). Each patient was randomized to three out of the five meters.…”
Section: Blood Glucose Monitoring System Accuracy Studymentioning
confidence: 99%
See 1 more Smart Citation
“…To assure quality and provide valuable references for choosing reliable BG meters in the current market, accuracy evaluation of BGMs has been performed extensively by both manufactures and third-party institutions (ie, Institute for Diabetes Technology). [12][13][14] In the past 5 years, there were 21 and 15 large evaluations on the performance of BGMs manufactured in the regions of Europe and North America, respectively, [12][13][14][15][16][17][18][19][20] whereas only 5 studies mentioned a few BGMs manufactured in the Asia-Pacific region. [12][13][14]21,22 Not one single large data was published on BGMs manufactured in different regions of Asia.…”
mentioning
confidence: 99%