2017
DOI: 10.4047/jap.2017.9.4.287
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

Abstract: PURPOSETo compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression.MATERIALS AND METHODSA machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 32 publications
0
6
0
Order By: Relevance
“…Another measuring method that has been described is via image measuring software. Images were taken through a digital camera [31], or a digital camera attached to a microscope [32,33], and then measurements were taken through calibrated image software. For the present investigation, we used a laboratory scanner to scan all the models, and then STL files were processed through three-dimensional analysis software to produce all the measurements.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Another measuring method that has been described is via image measuring software. Images were taken through a digital camera [31], or a digital camera attached to a microscope [32,33], and then measurements were taken through calibrated image software. For the present investigation, we used a laboratory scanner to scan all the models, and then STL files were processed through three-dimensional analysis software to produce all the measurements.…”
Section: Discussionmentioning
confidence: 99%
“…Even though, in some studies, varying undercuts were made at the cervical part of metal dies [26,32], those simplified master models cannot safely simulate clinical conditions. In order to get clinically relevant results, we tried to recreate a common clinical situation by using three metal dies in a partial edentulous arch, similar to two other studies [21,33]. The dies simulated full-crown preparations, two for a FPD and one for a single crown at the opposite site.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The putty material in the one-step putty/wash technique also tends to push the wash impression material away from the prepared tooth and from important areas such as the finish line, which can be obscured by the putty material and thus cannot record detail satisfactorily. [22][23][24] The disadvantage of the putty index method is that some of the wash impression material can spread occlusally when the putty impression material is placed back or when the wash material is introduced. This can cause distortion that reduces dimensional accuracy.…”
Section: Discussionmentioning
confidence: 99%
“…In the initial step, separating foils (Plicafol, GS Folienfertigung, Lebach, Germany) were applied on the external tooth surfaces, and the preliminary impression was made by putty material. After the setting time, the foil was detached and then the next phase of impression was made with low-viscosity material and poured with type IV dental stone (GC Fujirock EP, GC Corp, Leuven, Belgium) (16). The wax patterns were prepared with a flat occlusal surface and 0.5 mm thickness using type I blue inlay wax (Kerr/Sybron, Orange, CA, USA).…”
Section: Tooth Preparationmentioning
confidence: 99%