DOI: 10.1007/s10450-020-00281-w
|View full text |Cite
|
Sign up to set email alerts
|

Accurate blank corrections for zero length column experiments

Abstract: In this study we present a new methodology for correcting experimental Zero Length Column data, to account for contributions to the measured signal arising from extra-column volumes and the detector. The methodology considers the experimental setup as a series of mixing volumes with diffusive pockets whose contributions to the overall measured signal can be accurately described by simple model functions. The composite effect of the individual contributions is subsequently described through the method of convol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 14 publications
(14 citation statements)
references
References 27 publications
0
14
0
Order By: Relevance
“…Prior to ZLC measurements, the samples were activated overnight at 523 K (Na 6.2 -, Cs 6.2 -MER) or 573 K (K 6.2 -MER) under a flow of helium. The as-received signals were corrected to account for effects which are intrinsic to the experimental setup, by means of a deconvolution procedure as described in Verbraeken et al 30 This procedure yields the concentration of the gas as it leaves the column and removes extra-column contributions, such as those arising from the detector. The materials' potential for gas separation was tested via breakthrough experiments.…”
Section: ■ Methodsmentioning
confidence: 99%
“…Prior to ZLC measurements, the samples were activated overnight at 523 K (Na 6.2 -, Cs 6.2 -MER) or 573 K (K 6.2 -MER) under a flow of helium. The as-received signals were corrected to account for effects which are intrinsic to the experimental setup, by means of a deconvolution procedure as described in Verbraeken et al 30 This procedure yields the concentration of the gas as it leaves the column and removes extra-column contributions, such as those arising from the detector. The materials' potential for gas separation was tested via breakthrough experiments.…”
Section: ■ Methodsmentioning
confidence: 99%
“…To enable analysis of both breakthrough and ZLC results, blank runs were also carried out [51] . These consist of repeating the column experiments under the same conditions as described above, but without adsorbent.…”
Section: Methodsmentioning
confidence: 99%
“…To enable analysis of both breakthrough and ZLC results, blank runs were also carried out. [51] These consist of repeating the column experiments under the same conditions as described above, but without adsorbent. In this case the column is filled with 2 mm glass beads to give a pressure drop and void fraction close to that observed in the presence of the samples.…”
Section: Methodsmentioning
confidence: 99%
“…Of additional importance is the extra-column volume upstream of the bed. The upstream volume from the valve to the bed should be fully swept so as to avoid the complications associated with stranded pockets of gas which can complicate the analysis of the breakthrough curves [31]. To meet these requirements, a Bronkhorst Mini-Cori M12 coriolis mass flow meter (200 ± 0.02 g/hr) was installed upstream of the adsorbate gas mass flow controller, MFC-2.…”
Section: Micro Dynamic Column Breakthrough Apparatusmentioning
confidence: 99%