Accurate commissural alignment during ACURATE neo TAVI procedure. Proof of concept

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
20
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(20 citation statements)
references
References 15 publications
0
20
0
Order By: Relevance
“…Optimising transcatheter aortic valve commissural alignment in native annulus may avoid coronary artery overlap and facilitate coronary access in the future, especially using certain types of self-expandable transcatheter bioprostheses (Evolut from Medtronic and ACURATE-neo from Boston Scientific). [ 52 56 ] Redondo et al developed a promising method for proper commissural alignment (ACURATE-neo bioprosthesis) to insert the delivery system with a patient-specific rotation based on CT data analysis, tested in 3D, printed in silico models and in vivo. [ 56 ] The results suggested an important reduction in commissural misalignment and coronary artery overlap.…”
Section: Intervention In Tavi Patientsmentioning
confidence: 99%
See 2 more Smart Citations
“…Optimising transcatheter aortic valve commissural alignment in native annulus may avoid coronary artery overlap and facilitate coronary access in the future, especially using certain types of self-expandable transcatheter bioprostheses (Evolut from Medtronic and ACURATE-neo from Boston Scientific). [ 52 56 ] Redondo et al developed a promising method for proper commissural alignment (ACURATE-neo bioprosthesis) to insert the delivery system with a patient-specific rotation based on CT data analysis, tested in 3D, printed in silico models and in vivo. [ 56 ] The results suggested an important reduction in commissural misalignment and coronary artery overlap.…”
Section: Intervention In Tavi Patientsmentioning
confidence: 99%
“…[ 52 56 ] Redondo et al developed a promising method for proper commissural alignment (ACURATE-neo bioprosthesis) to insert the delivery system with a patient-specific rotation based on CT data analysis, tested in 3D, printed in silico models and in vivo. [ 56 ] The results suggested an important reduction in commissural misalignment and coronary artery overlap. [ 56 ]…”
Section: Intervention In Tavi Patientsmentioning
confidence: 99%
See 1 more Smart Citation
“…One such shortcoming is that commissural alignment of transcatheter heart valves (THV) appears to be random; meaning that the THV neo-commissures can misalign with the native commissures of the aortic valve during deployment or self-expansion ( 5 , 6 ). In contrast; bioprosthetic valves used in SAVR can be reliably aligned correctly; commissure-to-commissure with the native valve ( 7 ). In TAVR; the misalignment may result in the THV neo-commissures partially or fully overlapping the coronary artery ostia ( 5 , 6 ).…”
Section: Introductionmentioning
confidence: 99%
“…In TAVR; the misalignment may result in the THV neo-commissures partially or fully overlapping the coronary artery ostia ( 5 , 6 ). As a result; complications can arise if a younger patient needs a percutaneous coronary intervention or redo-TAVR especially since some of them will present with ischemic heart disease later in life ( 5 , 7 ). With commissural misalignment there is also an increased risk of a leak during diastole because of the unnatural orientation of the THV; this may add undue stress to the THV leaflets ( 7 ).…”
Section: Introductionmentioning
confidence: 99%