2015
DOI: 10.1111/j.1751-908x.2015.00315.x
|View full text |Cite
|
Sign up to set email alerts
|

Accurate Determination of Sr Isotopic Compositions in Clinopyroxene and Silicate Glasses by LAMCICPMS

Abstract: The low‐Sr content (generally < 100 μg g−1) in clinopyroxene from peridotite makes accurate Sr isotopic determination by LA‐MC‐ICP‐MS a challenge. The effects of adding N2 to the sample gas and using a guard electrode (GE) on instrumental sensitivity for Sr isotopic determination by LA‐MC‐ICP‐MS were investigated. Results revealed no significant sensitivity enhancement of Sr by adding N2 to the ICP. Although using a GE led to a two‐fold sensitivity enhancement, it significantly increased the yield of polyatomi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
45
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 116 publications
(45 citation statements)
references
References 51 publications
0
45
0
Order By: Relevance
“…For example, the application of shield torch can reduce the electric potential difference between the plasma and the tip of the sampling cone, thus the doubly charged ion yield can be reduced Gray, 1986). While the shield torch can significantly increase the polyatomic ion yield, for example, the interferences of Ca-related and TiAr þ ions on Sr isotopes can be elevated (Tong et al, 2015). The doubly charged ion yield and polyatomic ion yield can be optimized by adjusting instrument parameters such as flow rate of nebulizer gas, sampling depth and RF power .…”
Section: Interferences Eliminationmentioning
confidence: 98%
See 4 more Smart Citations
“…For example, the application of shield torch can reduce the electric potential difference between the plasma and the tip of the sampling cone, thus the doubly charged ion yield can be reduced Gray, 1986). While the shield torch can significantly increase the polyatomic ion yield, for example, the interferences of Ca-related and TiAr þ ions on Sr isotopes can be elevated (Tong et al, 2015). The doubly charged ion yield and polyatomic ion yield can be optimized by adjusting instrument parameters such as flow rate of nebulizer gas, sampling depth and RF power .…”
Section: Interferences Eliminationmentioning
confidence: 98%
“…The data reduction of Sr isotopic ratios includes corrections for background, isobaric interference and instrumental mass fractionation (Ramos et al, 2004;Tong et al, 2015;Vroon et al, 2008;Yang et al, 2009). The gas blank measurement was made to eliminate the effect of the small, persistent yet stable Rb and Sr backgrounds from the torch and cones, as well as Kr from the argon and helium supplies.…”
Section: Sr and Os Isotopic Analysesmentioning
confidence: 99%
See 3 more Smart Citations