2022
DOI: 10.1016/j.survophthal.2021.05.012
|View full text |Cite
|
Sign up to set email alerts
|

Adaptive optics ophthalmoscopy: a systematic review of vascular biomarkers

Abstract: parietal thickness (PT), wall cross-sectional area (WCSA), and wall-to-lumen ratio (WLR). The applicability of AO vascular biomarkers has been mostly explored in systemic hypertension using AO FIO and in diabetes using AO SLO. The result of the meta-analysis for hypertensive patients showed that WLR, PT, and ID were significantly different when compared to healthy controls, while WCSA was not (P < 0.001, P = 0.002, P < 0.001, and P = 0.070, respectively). The presented review shows that, although a substantial… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
21
0
4

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 33 publications
(41 citation statements)
references
References 71 publications
4
21
0
4
Order By: Relevance
“…Coupling OCTA and adaptive optics may be an exciting avenue. Adaptive optics is another novel ocular imaging approach that provides in vivo ultra-high-resolution imaging of retinal vessel morphology in humans ( 30 ).…”
Section: Potential Octa Measures Of Microcirculation In Systemic Hypertensionmentioning
confidence: 99%
“…Coupling OCTA and adaptive optics may be an exciting avenue. Adaptive optics is another novel ocular imaging approach that provides in vivo ultra-high-resolution imaging of retinal vessel morphology in humans ( 30 ).…”
Section: Potential Octa Measures Of Microcirculation In Systemic Hypertensionmentioning
confidence: 99%
“…Technology of adaptive optics (AO) has been applied to retinal imaging in DR [ 48 ]. The AO-SLO camera enables us to observe retinal structure at the cellular level or the dynamics of the cell flow of the inner retina.…”
Section: Evolutions Of Contemporary Modalities In Imaging Of Drmentioning
confidence: 99%
“…There is also growing interest in the use of ophthalmic adaptive optics (AO) for retinal vascular biomarkers [125]. A significant association of the retinal vascular structure (inner and outer diameter, parietal thickness) with hypertension has been found [126,127]. Recently, Zhang et al applied automatic segmentation of microaneurysms from AO with success [128].…”
Section: Ai and Other Retinal Imaging Parametersmentioning
confidence: 99%