2017
DOI: 10.1016/j.jid.2016.08.010
|View full text |Cite
|
Sign up to set email alerts
|

Adipose Tissue-Derived Microvascular Fragments Improve Vascularization, Lymphangiogenesis, and Integration of Dermal Skin Substitutes

Abstract: Full-thickness skin defects can be covered with dermal skin substitutes in combination with split-thickness skin grafts. However, slow vascularization of the matrices bears the risk of wound infection and extends the length of hospitalization. To overcome these problems, we describe a promising vascularization strategy. Green fluorescent protein adipose tissue-derived microvascular fragments (ad-MVF) were isolated from epididymal fat pads of C57BL/6-Tg(CAG-EGFP)1Osb/J mice. ad-MVF were seeded on collagen-glyco… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
103
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 76 publications
(110 citation statements)
references
References 36 publications
7
103
0
Order By: Relevance
“…As previously described in detail, ad-MVF were isolated from epididymal fat pads of GFP + donor mice (Frueh et al, 2017). Briefly, the bilateral epididymal fat pads were removed, transferred into 10 % Dulbecco's modified eagle medium (DMEM; 100 U/mL penicillin, 0.1 mg/mL streptomycin; Biochrom, Berlin, Germany) and washed thrice with phosphate-buffered saline (PBS).…”
Section: Isolation Of Ad-mvfmentioning
confidence: 99%
See 4 more Smart Citations
“…As previously described in detail, ad-MVF were isolated from epididymal fat pads of GFP + donor mice (Frueh et al, 2017). Briefly, the bilateral epididymal fat pads were removed, transferred into 10 % Dulbecco's modified eagle medium (DMEM; 100 U/mL penicillin, 0.1 mg/mL streptomycin; Biochrom, Berlin, Germany) and washed thrice with phosphate-buffered saline (PBS).…”
Section: Isolation Of Ad-mvfmentioning
confidence: 99%
“…To quantify the collagen content of implanted MWD and FWM, additional sections were stained with sirius red. Using a BX60 microscope (Olympus, Hamburg, Germany) and the imaging software cellSens Dimension 1.11 (Olympus), the collagen content was assessed in relation to normal skin in 4 ROIs per sample (Frueh et al, 2017 (Olympus) to assess the distribution and the distance of individual ad-MVF within the samples. For this purpose, the number of CD31 + microvessels was determined in 20 ROIs per implant (equivalent to the entire implant area per section), to calculate the coefficient of variation (cv; standard deviation/mean) of the spatial fragment distribution.…”
Section: T Später Et Almentioning
confidence: 99%
See 3 more Smart Citations