2015
DOI: 10.1021/acs.jpcc.5b03208
|View full text |Cite
|
Sign up to set email alerts
|

Adsorption and Aggregation at Silica/Methanol Interfaces: The Role of Solute Structure

Abstract: Second harmonic generation (SHG) and time-resolved, total internal reflection fluorescence (TR-TIRF) spectroscopy were used to examine the adsorption, solvation, and aggregation of a coumarin solute, Coumarin 152 (C152), at the silica/methanol interface. Experiments were performed as a function of bulk C152 concentration with SHG data providing information about relative surface coverage and ground state solvation environment. TR-TIRF data measured emission lifetimes of C152 adsorbed to the silica/methanol int… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6

Relationship

6
0

Authors

Journals

citations
Cited by 12 publications
(17 citation statements)
references
References 48 publications
0
17
0
Order By: Relevance
“…A small but measurable fraction of C152's emission fits to a much longer lifetime (4.02 ns) that has been assigned previously to dimers in solution. 15 For TIR measurements carried out at the silica/aqueous interface, the fluorescence decay from a saturated C152 solution is best fit with two lifetimes: a short 0.47 ns lifetime assigned to C152 in bulk solution and a longer lifetime of 3.52 ns assigned to C152 adsorbed to the surface (Figure 3). Normalized amplitudes for the short and long lifetimes are 0.87 and 0.13, respectively.…”
Section: ■ Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…A small but measurable fraction of C152's emission fits to a much longer lifetime (4.02 ns) that has been assigned previously to dimers in solution. 15 For TIR measurements carried out at the silica/aqueous interface, the fluorescence decay from a saturated C152 solution is best fit with two lifetimes: a short 0.47 ns lifetime assigned to C152 in bulk solution and a longer lifetime of 3.52 ns assigned to C152 adsorbed to the surface (Figure 3). Normalized amplitudes for the short and long lifetimes are 0.87 and 0.13, respectively.…”
Section: ■ Resultsmentioning
confidence: 99%
“…Experiments were carried out using a locally constructed time-correlated single photon counting (TCSPC) fluorometer that has been described previously . The output of a Ti:sapphire oscillator (Chameleon, Coherent) was frequency doubled (APE Autotracker), and the 80 MHz repetition rate was attenuated to 4 MHz using an electro-optic modulator (Conoptics model 350-105).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Photon emission was collected at 500 nm. Additional details about this assembly can be found in previous reports. ,, …”
Section: Experimental Methodsmentioning
confidence: 99%
“…Additional details about this assembly can be found in previous reports. 21,26,32 In a given TCSPC experiment, signal was collected until the maximum intensity at early times reached a threshold of 8000 counts. Depending on the local solvation environment of the solute (and thus radiative rate and fluorescence quantum yield), the time required for each experiment varied with temperature.…”
mentioning