2022
DOI: 10.1016/j.chroma.2021.462693
|View full text |Cite
|
Sign up to set email alerts
|

Advanced score system and automated search strategies for parameter estimation in mechanistic chromatography modeling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 41 publications
0
7
0
Order By: Relevance
“…The sum of squared differences between the simulated chromatogram and the experimental chromatogram is frequently used as an objective function to assess the quality of the model prediction. This objective function is sensitive to the relative timings of the elution peaks rather than their shapes, leading to recommendations for a new objective function system specifically designed for chromatography modeling (Heymann et al, 2022). This system utilizes the Frontiers in Bioengineering and Biotechnology frontiersin.org "shape" objective function, which is measured by the maximum of the Pearson correlation coefficient between the simulated and the experimental chromatogram over a continuous range of time offsets.…”
Section: Challenge Iii: Effects Not Yet Represented In Chromatography...mentioning
confidence: 99%
See 4 more Smart Citations
“…The sum of squared differences between the simulated chromatogram and the experimental chromatogram is frequently used as an objective function to assess the quality of the model prediction. This objective function is sensitive to the relative timings of the elution peaks rather than their shapes, leading to recommendations for a new objective function system specifically designed for chromatography modeling (Heymann et al, 2022). This system utilizes the Frontiers in Bioengineering and Biotechnology frontiersin.org "shape" objective function, which is measured by the maximum of the Pearson correlation coefficient between the simulated and the experimental chromatogram over a continuous range of time offsets.…”
Section: Challenge Iii: Effects Not Yet Represented In Chromatography...mentioning
confidence: 99%
“…Importantly, the corresponding parameters are interdependent during model calibration. For example, an inaccurately determined column porosity can distorted the value calculated for the equilibrium constant when fitting a chromatography model to a given peak ( Heymann et al, 2022 ). Various methods have been proposed to determine equilibrium parameters ( Shukla et al, 1998 ; Osberghaus et al, 2012a ; Bernau et al, 2021 ) but the experimental determination of different types of liquid volumes in columns remains challenging, especially for packed-bed chromatography using porous, spherical beads as the stationary phase.…”
Section: Challenge Ii: Obtaining Experimental Data To Set Up the Modelmentioning
confidence: 99%
See 3 more Smart Citations