Aerosol dilution as a simple strategy for analysis of complex samples by ICP-MS

Abstract: This study investigated the capability of High Matrix Introduction (HMI) strategy for analysis of dialysis solution and urine samples using inductively coupled plasma mass spectrometry. The use of HMI enables the direct introduction of urine samples and dialysis solutions 2-fold diluted with 0.14molL HNO. Bismuth, Ge, Ir, Li, Pt, Rh, Sc and Tl were evaluated as internal standards for Al, Ag, As, Be, Cd, Cr, Pb, Sb, Se, Tl, and Hg determination in dialysis solution and As, Cd, Hg and Pb determination in urine s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
21
0
4

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 36 publications
(26 citation statements)
references
References 23 publications
1
21
0
4
Order By: Relevance
“…IS was not required for accurate determination of 9 27 Al and 55 Mn probably may be due to the similarity of the mass to charge ratios, m/z, of the IS evaluated with the analytes. 19 However, as demonstrated by Barros et al 18 and also obtained here, significant improvement of recoveries (110 and 118%) were also reached with 193 Ir as IS for 27 Al.…”
Section: Effect Of the Hmi System For Analysis Of Saline Solutionssupporting
confidence: 85%
See 1 more Smart Citation
“…IS was not required for accurate determination of 9 27 Al and 55 Mn probably may be due to the similarity of the mass to charge ratios, m/z, of the IS evaluated with the analytes. 19 However, as demonstrated by Barros et al 18 and also obtained here, significant improvement of recoveries (110 and 118%) were also reached with 193 Ir as IS for 27 Al.…”
Section: Effect Of the Hmi System For Analysis Of Saline Solutionssupporting
confidence: 85%
“…The use of HMI system (in the same dilution gas flow rate of 0.60 L min -1 ) enabled the direct introduction of urine samples and dialysis solutions 2-fold diluted. 18 Figure 2 shows an increase of oxide formation when increasing NaCl concentration, probably this is due to the decrease of plasma energy caused by plasma loading, in consequence of the presence of sample matrix. However, by increasing HMI gas flow rate (> 0.50 L min -1 ) it was observed that CeO + /Ce + ratio did not vary significantly in most NaCl concentrations.…”
Section: Effect Of the Hmi System For Analysis Of Saline Solutionsmentioning
confidence: 96%
“…However, as it is common in IS studies, there were some exceptions: 115 In + was the best IS for 50 V + , and 103 Rh + was the best IS for 63 Cu + . Barros et al ( 2018 ) also observed divergences when studying the criteria for selecting the best IS in ICP-MS. They observed improvement in recoveries for 9 Be when 7 Li was used as IS, which may be attributed to the similar mass-to-charge ratios ( m/z ).…”
Section: Traditional Calibration Methodsmentioning
confidence: 99%
“…Some recent studies reported using an aerosol dilution technique as a simple strategy for the analysis of high matrix samples; 31 , 32 however, they can only measure samples with quite low TDS (less than 3%) and with a relatively large volume (>5 mL sample). For high TDS samples, 33 developed a method using ICP-MS coupled with an ultra-high matrix introduction system (UHMI) to measure Eu and U in highly saline samples (up to 5 mol L –1 NaCl), but such a method requires 100 times on-line dilution for the samples, and therefore is not suitable for analysing elements with low initial concentrations.…”
Section: Introductionmentioning
confidence: 99%