2013
DOI: 10.1007/s12161-013-9675-8
|View full text |Cite
|
Sign up to set email alerts
|

Aerosol Dilution Technique for Direct Determination of Ultra-Trace Levels of Cr, Mn, Fe, Co, Ni, Cu, and Zn in Edible Salt Samples by Collision/Reaction Cell Inductively Coupled Plasma Mass Spectrometry (CRC-ICP-MS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
17
1

Year Published

2014
2014
2020
2020

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(19 citation statements)
references
References 17 publications
1
17
1
Order By: Relevance
“…It is nutritionally essential for humans and is a component of more than twenty selenoproteins that play a critical part in reproduction, DNA synthesis, thyroid hormone metabolism, and protection from oxidative insult and infection [ 26 ]. The highest Se concentration was 65.9 ppb in the sample of Hatay province while our data is similar to other Anatolian honey samples [ 11 , 21 ]. For Se concentrations determined in this study, the mean concentration was very high compared to Argentine honey samples with the mean of 10 ppb [ 5 ].…”
Section: Resultssupporting
confidence: 88%
See 1 more Smart Citation
“…It is nutritionally essential for humans and is a component of more than twenty selenoproteins that play a critical part in reproduction, DNA synthesis, thyroid hormone metabolism, and protection from oxidative insult and infection [ 26 ]. The highest Se concentration was 65.9 ppb in the sample of Hatay province while our data is similar to other Anatolian honey samples [ 11 , 21 ]. For Se concentrations determined in this study, the mean concentration was very high compared to Argentine honey samples with the mean of 10 ppb [ 5 ].…”
Section: Resultssupporting
confidence: 88%
“…Toxic metal levels of honey depend on the biological and geographical origin [ 10 ]. ICP-MS is a good technique with simultaneous determinations of elements, high sensitivity, capability, and wide linear range [ 11 ].…”
Section: Introductionmentioning
confidence: 99%
“…Sea water is a high TDS matrix for plasma. Additionally, elemental detection in an NaCl matrix by ICP-MS is also affected by polyatomic interferences formed by chlorine ions, such as 35 Cl 16 75 As + in quadrupole based mass spectrometers. 6,7 The effect of HMI use on chlorine interferences and oxide formation was evaluated by signal intensities monitoring for 75 As + 1.0 µg L -1 (Figure 1) and for CeO + /Ce + ratio ( Figure 2).…”
Section: Effect Of the Hmi System For Analysis Of Saline Solutionsmentioning
confidence: 99%
“…[7][8][9] Additionally, high matrix introduction (HMI) technology uses auto-optimization of aerosol dilution to further improve matrix tolerance, reducing both aerosol density and water vapor loading in the plasma. 8,[10][11][12][13][14][15][16] Wilbur and Jones 8 demonstrated the benefits of HMI system for determination of 26 elements in complex matrix certified reference materials (CRM), such as river sediment and soil samples. Aqueous samples were investigated using fast protein liquid chromatography (FPLC) coupled to ICP-MS with a high matrix introduction system.…”
Section: Introductionmentioning
confidence: 99%
“…Inductively coupled plasma-mass spectrometry (ICP-MS) is a powerful technique for the determination of elements in various samples, due to its multielemental capability, wide linear dynamic range, and high sensitivity (Batista et al 2012;Dö ker and Uslu 2014;Millour et al 2012;Dö ker et al 2010). However, interferences from sample components hamper the reliable determination of trace elements in honey.…”
Section: Introductionmentioning
confidence: 99%