This study presents the chromatographic purification of immunoglobulin G (IgG) from human plasma using a two‐column process integrating the peptide‐based adsorbents LigaGuard™, which captures non‐Ig plasma proteins in flow‐through mode, and LigaTrap™, which isolates IgG in bind‐and‐elute. Buffer composition and column loading were optimized for both adsorbents. Two process configurations were evaluated. In the first design, plasma was fed to a LigaGuard™ column to capture plasma proteins, the effluent was loaded on the LigaTrap™ column, and the bound IgG was eluted with 63.8% global recovery and 99.7% purity; in comparison, Protein G agarose afforded approximately 67% recovery and 97.2% purity. In the alternative design, the LigaGuard™ column was utilized to polish the LigaTrap™ elution stream, affording 82.3% global recovery and 98.8% purity. Collectively, these results demonstrate the potential of a fully chromatographic process for purifying polyclonal IgG from plasma feedstocks.