2013
DOI: 10.1016/j.sna.2013.01.042
|View full text |Cite
|
Sign up to set email alerts
|

Alcohol-filled side-hole fiber Sagnac interferometer for temperature measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
16
0
2

Year Published

2013
2013
2021
2021

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 38 publications
(19 citation statements)
references
References 15 publications
1
16
0
2
Order By: Relevance
“…After performing a suitable correction on the heated and unheated fiber lengths, the sensitivity was calculated to be (8.40 AE 0.06) nm/°C [8]. This sensitivity value compares well to the highest temperature sensitivity values reported in the literature such as 9.0[4], 6.6 [20], and 16.49 nm/°C [21], which were measured for photonic-crystal fibers filled with indium, ethanol, and index matching liquid, respectively. This once again demonstrates that embedded-core fibers are a very promising platform for the realization of high-sensitivity optical sensing.…”
Section: Embedded-core Capillary Fibers For Temperature Sensingsupporting
confidence: 58%
“…After performing a suitable correction on the heated and unheated fiber lengths, the sensitivity was calculated to be (8.40 AE 0.06) nm/°C [8]. This sensitivity value compares well to the highest temperature sensitivity values reported in the literature such as 9.0[4], 6.6 [20], and 16.49 nm/°C [21], which were measured for photonic-crystal fibers filled with indium, ethanol, and index matching liquid, respectively. This once again demonstrates that embedded-core fibers are a very promising platform for the realization of high-sensitivity optical sensing.…”
Section: Embedded-core Capillary Fibers For Temperature Sensingsupporting
confidence: 58%
“…Açık çevrim fiberoptik jiroskopun optik ve elektriksel bağlantılarını gösteren bağlantı şeması Şekil 1'de gösterilmiştir [9,15,16] işareti için kabul edilebilir ölçüttedir [23,24]. Geleneksel jiroskop için aynı doğrusallık ilişkisinde dinamik ölçüm aralığı ise 0-0,38 rad/s hesaplanmıştır.…”
Section: Teori̇ (Theory)unclassified
“…Currently, the development of optical fiber temperature sensors are mainly based on two technical routes: fiber grating based temperature sensors [6][7][8][9][10][11][12][13][14] and fiber interferometer based temperature sensors [15][16][17][18][19][20][21][22][23][24][25][26][27][28]. For fiber grating based temperature sensors, long period grating (LPG) is a common employed device [6][7][8][9][10].…”
Section: Introductionmentioning
confidence: 99%