2012 IEEE Energy Conversion Congress and Exposition (ECCE) 2012
DOI: 10.1109/ecce.2012.6342716
|View full text |Cite
|
Sign up to set email alerts
|

All-electric Wave Energy Converter array with energy storage and reactive power compensation for improved power quality

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
1
1

Relationship

4
4

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 4 publications
0
9
0
Order By: Relevance
“…In our earlier publication [13], we showed that the peak to average ratio would be directly reduced by a factor of 3-5 due to natural power smoothing between the devices. The peak-to-average ratio could be further improved towards 1.5 by implementing a small energy storage, as shown in our work [14]. As will be demonstrated in the following, the peak power rating for the current configuration is close to three, which will require a rated installed converter capacity of about twice the average exported power.…”
Section: Arraymentioning
confidence: 77%
See 2 more Smart Citations
“…In our earlier publication [13], we showed that the peak to average ratio would be directly reduced by a factor of 3-5 due to natural power smoothing between the devices. The peak-to-average ratio could be further improved towards 1.5 by implementing a small energy storage, as shown in our work [14]. As will be demonstrated in the following, the peak power rating for the current configuration is close to three, which will require a rated installed converter capacity of about twice the average exported power.…”
Section: Arraymentioning
confidence: 77%
“…Still, this will require a converter with twice the cost compared to an average exported power, and measures to further improve the power quality should be kept in mind. Our previously published paper [14] indicates a final peak-to-average ratio for the array between 1.5 and 3 after energy storage is included, the exact figure being a result of economic optimization. The total aggregate wave farm power is calculated by adding up the six array outputs.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Olsen [18]. Lifesaver is a toroid shape WEC equipped with five individual all-electric Power Take-Off (PTO) units.…”
Section: Model Of the Wave Power Generationmentioning
confidence: 99%
“…Previous estimations have been made for the Lifesaver concept [23], and some preliminary investigations have also been performed into a potential increase in annual energy production using reactive control. However, the latter paper does not take into account the generator force limitation or generator losses, and these factors become very significant under reactive control in particular [24].…”
Section: Energy Calculations-potential Increase In Annual Energy Prodmentioning
confidence: 99%