2011
DOI: 10.1166/sl.2011.1717
|View full text |Cite
|
Sign up to set email alerts
|

All-Solid-State Polyvinyl Chloride Membrane Lithium-Selective Electrode with Improved Selectivity and Its Application in Serum Lithium Assay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
15
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(16 citation statements)
references
References 0 publications
1
15
0
Order By: Relevance
“…Sensitivity is primarily controlled through selection of the chromoionophore and the ratio of the sensor components. Selectivity is controlled through the selection of the lithium ionophore and the addition of TOPO (Trioctylphosphine oxide), which has been shown to increase lithium selectivity in macroscale optodes 20 . We found a similar effect of TOPO on the selectivity of nanosensors (Supporting Fig.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Sensitivity is primarily controlled through selection of the chromoionophore and the ratio of the sensor components. Selectivity is controlled through the selection of the lithium ionophore and the addition of TOPO (Trioctylphosphine oxide), which has been shown to increase lithium selectivity in macroscale optodes 20 . We found a similar effect of TOPO on the selectivity of nanosensors (Supporting Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Lithium is a valuable model system for photoacoustic imaging because continuous measurement technologies such as photoacoustics can provide a method to track systemic concentrations of therapeutic drugs and improve disease management. Lithium is a common treatment for bipolar disorder, but it has both a narrow therapeutic window (0.6 – 1.2 mM) and a low toxic dose (~ 2 mM) 20-21 , demonstrating a need for continuous monitoring.…”
mentioning
confidence: 99%
“…An interesting possible alternative to these bulky and complicated methods could be represented by potentiometric all-solid-state ISEs as they enable simplicity of detection, easy miniaturization and low cost. Nonetheless, only a few examples have been proposed in the research community in this direction so far [9], [10], despite the huge impact that those remote monitoring systems could have on patients' quality of life. Carbon nanotubes have been used to fabricate a paper-based Li + ISE by Novell et al in [9].…”
Section: Introductionmentioning
confidence: 99%
“…Carbon nanotubes have been used to fabricate a paper-based Li + ISE by Novell et al in [9]. A small Li + sensor with high selectivity has been described by Coldur et.al in [10]. The system is based on the use of a graphite composite as solid contact.…”
Section: Introductionmentioning
confidence: 99%
“…A paper-based portable ISE with carbon nanotubes as SC has been demonstrated to measure lithium in serum [12]. A miniaturized Li + ISE with improved selectivity has been developed by using a graphite composite for transduction [13]. These devices certainly offer new interesting insights, however some major drawbacks still need to be overcome.…”
Section: Introductionmentioning
confidence: 99%