Alterations of hemostasis associated with cardiopulmonary bypass

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
73
0

Year Published

1984
1984
2014
2014

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 59 publications
(75 citation statements)
references
References 32 publications
2
73
0
Order By: Relevance
“…Results of the biological study confirmed that ECC provokes a decrease in the concen tration of several hemostatic factors [14,15], No differences were observed between the mean values obtained in the LMW, LD or HD heparin groups. The explanation for the slight decrease in fibrin, AT III, F V and AP is the combined effect of hemodilution and adsorption of these proteins on the interfaces [13,15], A moderate FDP elevation was ob served at To and during the ECC in the three groups of animals, probably as a result of sur gical procedure.…”
Section: Discussionsupporting
confidence: 55%
“…Results of the biological study confirmed that ECC provokes a decrease in the concen tration of several hemostatic factors [14,15], No differences were observed between the mean values obtained in the LMW, LD or HD heparin groups. The explanation for the slight decrease in fibrin, AT III, F V and AP is the combined effect of hemodilution and adsorption of these proteins on the interfaces [13,15], A moderate FDP elevation was ob served at To and during the ECC in the three groups of animals, probably as a result of sur gical procedure.…”
Section: Discussionsupporting
confidence: 55%
“…Perfusions of the circulatory system with devices like the cardiopulmonary bypass (CPB) and CAD disturb endothelial shear stress (ESS), which is responsible for the postcardiotomy syndrome, increasing liabilities of clot formation, bleeding, disseminated syndrome, etc (Bick et al, 1976)) (Abshire, 2009). This endothelial dysfunction syndrome is most probably occurred due to steady flow, foreign surfaces and the severe momentum energy losses.…”
Section: Evaluation Of the Pulsatile Tube Devicementioning
confidence: 99%
“…The hemostatic complications that accompany the insertion of prosthetic devices include activation of coagulation factors, 'consumption' of coagulation factors and other plasma proteins and platelets and the generation of microthrombi. Also, life-threatening thrombosis or thromboembolism may de- velop in those with prosthetic devices [2][3][4][5]60]. Intra-aortic balloon assist devices may activate the coagulation system with an attendant low-grade DIC, which may become fulminant [3].…”
Section: Etiologymentioning
confidence: 99%
“…Intra-aortic balloon assist devices may activate the coagulation system with an attendant low-grade DIC, which may become fulminant [3]. LeVeen or Denver valve shunting for peritoneovenous or pleurovenous shunting is a common palliative procedure and generalized DIC is often seen with the use of these shunts [2,3,60,61]. The removal of ascitic fluid at the time of LeVeen or Denver valve implantation, and the use of low-dose heparin may abort DIC [2][3][4][5].…”
Section: Etiologymentioning