2015
DOI: 10.1161/hypertensionaha.115.05734
|View full text |Cite
|
Sign up to set email alerts
|

Altered Retinal Flicker Response Indicates Microvascular Dysfunction in Women With Preeclampsia

Abstract: Abstract-Flicker-induced dilatation is reduced in patients with cardiovascular risk, and the following arteriolar constriction is reduced with aging, leading to a reduced arteriolar amplitude and, thereby, indicating microvascular endothelial dysfunction. As endothelial dysfunction is associated with preeclampsia, we assessed retinal flicker response during pregnancy and postpartum. Between 2006 and 2013, women were recruited from University Hospital Jena and Prenatal Diagnostic Center Erfurt, Germany, of whic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(18 citation statements)
references
References 35 publications
1
16
0
1
Order By: Relevance
“…The HEPAtonorm Analyzer is portable, adapted for a bedside use, the costs are limited and the measurement is easy to interpret. This is in contrast to the flicker analysis of our previous study, where we measured retinal vessels under the influence of flickering light, using a mydriatic fundus camera [13].…”
Section: Commentmentioning
confidence: 82%
See 1 more Smart Citation
“…The HEPAtonorm Analyzer is portable, adapted for a bedside use, the costs are limited and the measurement is easy to interpret. This is in contrast to the flicker analysis of our previous study, where we measured retinal vessels under the influence of flickering light, using a mydriatic fundus camera [13].…”
Section: Commentmentioning
confidence: 82%
“…Previously, we could show, that retinal vascular response under the influence of flickering light is altered in women with preeclampsia, indicating a commenced retinal microvascular dysfunction [13]. A completely new method arises with the assessment of critical flicker frequency (CFF), a simple and objective method to assess the visual and cognitive function [14,15].…”
Section: Introductionmentioning
confidence: 99%
“…A Dynamic Vessel Analyzer with flicker light stimulation (DVA; Imedos, Jena, Germany) was used for measurements of retinal vessel diameter. A detailed description of the study protocol was previously provided in other publications (9,14,15). In general, only the major temporal arterial and venous segments approximately 1.5 mm long were evaluated.…”
Section: Retinal Vessels Analysismentioning
confidence: 99%
“…Verschiedene methodologische Modalitäten der dynamischen retinalen Gefäßanalyse wurden entwickelt und in klinischen Studien an Gesunden und an Patienten mit Augenerkrankungen und systemischen Erkrankungen getestet: [47], Neurochirurgie [64,65], Nephrologie [66], Gynäkologie [46], Sportmedizin [28], Diabetologie [67 -69], Hypertensiologie [54,70] usw. durchgeführt.…”
Section: Dynamische Retinale Gefäßanalyseunclassified